11.8.8 Stairway Video Monitoring
Go To Full Code Chapter
11.8.8.1* General
11.8.8.1.1
For high-rise buildings having an occupant load of 4,000 or more persons, real-time remote monitoring of exit stair usage shall be provided in accordance with 11.8.8.2 through 11.8.8.4 and shall be displayed at the emergency command center.
11.8.8.1.2
11.8.8.1.3
11.8.8.2
11.8.8.3
Approved video monitoring equipment shall be provided for exit stairs above the level of exit discharge, at building height intervals not exceeding 5 stories, so that descent and ascent flows on the stairways, at the floor entry landings, can be remotely monitored.
11.8.8.4
Approved video monitoring equipment shall be provided, at locations stipulated by the authority having jurisdiction, for exit stairs below the level of exit discharge where levels are normally occupied by the public.
Related Code Sections
11.8.8 Special Structures and High-Rise Buildings, Stairway Video Monitoring
For high-rise buildings having an occupant load of 4,000 or more persons, real-time remote monitoring of exit stair usage shall be provided ...
11.8.8.1.1 Special Structures and High-Rise Buildings,
For high-rise buildings having an occupant load of 4,000 or more persons, real-time remote monitoring of exit stair usage shall be provided ...
11.8.8.1.2 Special Structures and High-Rise Buildings,
Where the monitoring system is integrated with a security system, the security system shall be in accordance with NFPA 731 ...
11.8.5.3.4 Special Structures and High-Rise Buildings,
Mechanical equipment for smokeproof enclosures Mechanical equipment required to conform with the requirements of Section 9.3 Stairway video ...
11.8.6.2 Special Structures and High-Rise Buildings,
department use with controlled access to the public telephone system Stairway video monitoring equipment as required by 11.8.8 ...