§235 Stairs in Non-Fireproof Tenements

Jump To Full Code Chapter
  1. Every non-fireproof tenement erected after May fifteen, nineteen hundred two, containing more than twenty-six apartments or suites of rooms above the entrance story shall have an additional stair for every additional twenty-six apartments or suites or fraction thereof; except that if such tenement contains not more than thirty-six apartments above the entrance story, in lieu of an additional stair the stairs, stair halls and entrance halls throughout the entire tenement may each be at least one-half wider than is specified in sections two hundred thirty-four, two hundred thirty-seven and two hundred thirty-eight.
  2. The number of apartments on any story in any non-fireproof tenement may be altered, if the number of living rooms on such story is not increased by more than twenty per centum. If the number of living rooms on any story or section thereof above the entrance story exceeds twenty, there shall be an additional stair for each twenty rooms or fraction thereof on any such story or section thereof, except that if the number of living rooms on any such story or section does not exceed thirty, in lieu of an additional stair one stair and every public hall connected therewith may be at least one-half wider than is specified in sections two hundred thirty-four, two hundred thirty-seven and two hundred thirty-eight.
  3. Whenever the total number of rooms, exclusive of bathrooms, water-closet compartments, and cooking spaces less than eighty square feet in area, in any non-fireproof tenement or section thereof is decreased through the process of an alteration, the number of apartments may be altered and the provisions of this section which relate to additional stairs shall not be applicable.

Related Code Sections

§235 Tenements, Stairs in Non-Fireproof Tenements
Every non-fireproof tenement erected after May fifteen, nineteen hundred two, containing more than twenty-six apartments or suites of rooms above ...
§243 Tenements, Cellar and Basement Stairs in Fireproof Tenements
In fireproof tenements erected after April eighteenth, nineteen hundred twelve, the cellar and basement stairs shall be located, arranged ...
§218 Tenements, Alterations
Any non-fireproof tenement erected after May fifteenth, nineteen hundred two, having apartments extending from street to yard and having one ...
§239 Tenements, Tower Fire-Escapes and Supplemental Stairs
In fireproof tenements tower fire-escapes or stairs which are supplemental to the stairs required by law may be installed providing such tower fire ...
§233 Tenements, Bulkheads and Scuttles
Every tenement, except as in this section otherwise provided, shall have in the roof a fireproof bulkhead with a fireproof door and after January ...