Existing stairways shall comply with the requirements of these provisions. The code official shall grant alternatives for stairways and railings if alternative stairways are found to be acceptable or are judged to meet the intent of these provisions. Existing stairways shall comply with Section 1203.
Exception: For buildings less than 3,000 square feet (279 m2), existing conditions are permitted to remain at all stairs and rails.

Related Code Sections

1104.13 Construction Requirements for Existing Buildings, Stairway Handrails
Stairways shall have handrails on at least one side. Handrails shall be located so that all portions of the stairway width required for egress ...
1203.9 Historic Buildings, Stairway Railings
Grand stairways shall be accepted without complying with the handrail and guard requirements. Existing handrails and guards at all stairs shall ...
1205.11 Historic Buildings, Stairs and Railings
Existing stairways shall comply with the requirements of these provisions. The code official shall grant alternatives for stairways and railings ...
R311.7.8.2 Building Planning, Handrail Projection
Handrails shall not project more than 41/2 inches (114 mm) on either side of the stairway. Exception: Where nosings of landings, floors or passing ...
R311.7.7.1 Building Planning, Height
Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 ...