On the stair side, signs shall be posted and maintained at all stair doors at every floor. Such signs shall be either:
  1. Reentry. Where reentry is provided, a sign shall read, "REENTRY ON THIS FLOOR."
  2. No Reentry. Where reentry is not provided on that floor, the sign shall read:
    1. "NO REENTRY"; where reentry is not provided on any floor;
    2. "NO REENTRY, NEAREST REENTRY ON THE AND FLOORS"; where reentry is provided on other floors; and
    3. "NO REENTRY. REENTRY IS PROVIDED ONLY DURING FIRE EMERGENCIES. NEAREST TELEPHONE ON THE AND FLOORS"; where stair side doors are locked in accordance with Section 403.5.3.

Related Code Sections

1026.4.2 Means of Egress, Stair Side
On the stair side, signs shall be posted and maintained at all stair doors at every floor. Such signs shall be either:   1. Re-entry ...
1030.4.2 Means of Egress, Stair Side
On the stair side, signs shall be posted and maintained at all stair doors at every floor. Such signs shall be either: Reentry. Where reentry ...
1031.4.2 Means of Egress, Stair Side
On the stair side, signs shall be posted and maintained at all stair doors at every floor. Such signs shall be either: Reentry. Where reentry ...
403.12 Special Detailed Requirements Based on Use and Occupancy, Stairway Door Operation
Doors opening into interior stair enclosures shall not be locked from either side. However, a door locked from the stair side may be permitted ...