Existing stairs in buildings shall be permitted to remain if the rise does not exceed 81/4 inches (210 mm) and the run is not less than 9 inches (229 mm). Existing stairs can be rebuilt.
Exception: Other stairs approved by the fire code official.
1104.10.1 Dimensions for Replacement Stairs
The replacement of an existing stairway in a structure shall not be required to comply with the new stairway requirements of Section 1009 where the existing space and construction will not allow a reduction in pitch or slope.

Related Code Sections

3406.4 Existing Buildings and Structures, Dimensions
Stairs shall be at least 22 inches (559 mm) wide with risers not more than, and treads not less than, 8 inches (203 mm) and landings at the foot ...
3408.3 Existing Buildings and Structures, Stairways
An existing stairway shall not be required to comply with the requirements of Section 1009 where the existing space and construction does not allow ...
407.3 Prescriptive Compliance Method, Stairways
An existing stairway shall not be required to comply with the requirements of Section 1009 of the Interntional Building Code where the existing space ...
1012.7.2 Change of Occupancy, Stairways
only one adjacent floor and that are not connected with corridors or stairways serving other floors. Unenclosed existing stairways need ...