• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

410.2.1 Stage Construction

Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 410 Stages, Platforms and Technical Production Areas > 410.2 Stages > 410.2.1 Stage Construction
JUMP TO FULL CODE CHAPTER
Stages shall be constructed of materials as required for floors for the type of construction of the building in which such stages are located.
Exception: Stages need not be constructed of the same materials as required for the type of construction provided that the construction complies with one of the following:
  1. Stages of Type IIB or IV construction with a nominal 2-inch (51 mm) wood deck, provided that the stage is separated from other areas in accordance with Section 410.2.4.
  2. In buildings of Type IIA, IIIA and VA construction, a fire-resistance-rated floor is not required, provided that the space below the stage is equipped with an automatic sprinkler system or fire-extinguishing system in accordance with Section 903 or 904.
  3. In all types of construction, the finished floor shall be constructed of wood or approved noncombustible materials. Openings through stage floors shall be equipped with tight-fitting, solid wood trap doors with approved safety locks.

410.2.1.1 Stage Height and Area

Stage areas shall be measured to include the entire performance area and adjacent backstage and support areas not separated from the performance area by fire-resistance-rated construction. Stage height shall be measured from the lowest point on the stage floor to the highest point of the roof or floor deck above the stage.

Related Code Sections


410.2.1 Special Detailed Requirements Based on Occupancy and Use, Stage Construction
Stages shall be constructed of materials as required for floors for the type of construction of the building in which such stages are located ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 410 Stages, Platforms and Technical Production Areas > 410.2 Stages > 410.2.1 Stage Construction
410.2.1 Special Detailed Requirements Based on Occupancy and Use, Stage Construction
Stages shall be constructed of materials as required for floors for the type of construction of the building in which such stages are located ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 410 Stages, Platforms and Technical Production Areas > 410.2 Stages > 410.2.1 Stage Construction
1901.5 Concrete, Construction Documents
or stages of construction for which each concrete element is designed. The specified strength or grade of reinforcement. The size and location ...
Building Code 2021 of Illinois > 19 Concrete > 1901 General > 1901.5 Construction Documents
1901.5 Concrete, Construction Documents
or stages of construction for which each concrete element is designed. The specified strength or grade of reinforcement. The size and location ...
Building Code 2018 of Illinois > 19 Concrete > 1901 General > 1901.5 Construction Documents
Section 890.1950 Inspections, Tests, Maintenance and Administration, Violations
the nature and complexity of the violation, the stage of construction, the type of violation involved, the weather, and whether or not the violation ...
Illinois Plumbing Code > M Inspections, Tests, Maintenance and Administration > 890.1950 Violations
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING