Scenery battens and suspension systems shall be designed for a load of 30 pounds per linear foot (437.7 N/m) of batten length. Loft block and head block beams shall be designed to support vertical and horizontal loads corresponding to a 4-inch (101.6 mm) spacing of battens for the entire depth of the gridiron. Direction and magnitude of total forces shall be determined from the geometry of the rigging system including load concentrations from spot line rigging. Locking rails shall be designed for a uniform uplift of 500 psf (3447 kN/m2) with a 1,000 pound (454 kg) concentration. Impact factor for batten design shall be 75 percent and for loft and head block beams shall be 25 percent. A plan drawn to a scale not less than 1/4 inch (6.4 mm) equals 1 foot (304.8 mm) shall be displayed in the stage area indicating the framing plan of the rigging loft and the design loads for all members used to support scenery or rigging. Gridirons over stages shall be designed to support a uniformly distributed live load of 50 psf (2.40 kN/m2) in addition to the rigging loads indicated.

Related Code Sections

1607.2.1 Structural Design, Stage Areas Using Scenery or Scenic Elements
used to support scenery or rigging. Gridirons over stages shall be designed to support a uniformly distributed live load of 50 psf (2.40 kN/m2 ...
1607.2.1 Structural Design, Stage Areas Using Scenery or Scenic Elements
) equals one foot (305 mm) shall be displayed in the stage area indicating the framing plan of the rigging loft and the design loads for all members used ...
1607.2.1 Structural Design, Stage Areas Using Scenery or Scenic Elements
) equals 1 foot (305 mm) shall be displayed in the stage area indicating the framing plan of the rigging loft and the design loads for all members used ...
§27-560 Loads, Stage Areas Using Scenery or Scenic Elements
equals one foot shall be displayed in the stage area indicating the framing plan of the rigging loft and the design loads for all members used ...
§27-532 Places of Assembly, Aisles and Cross Aisles
not be closer than twelve feet to a stage area using scenery or scenic elements. Steppings shall not be permitted in cross aisles. (7) AISLE GRADIENTS AND ...