1010.2.1 Stadiums
JUMP TO FULL CODE CHAPTER
Panic hardware is not required on gates surrounding stadiums where such gates are under constant immediate supervision while the public is present, and where safe dispersal areas based on 3 square feet (0.28 m2) per occupant are located between the fence and enclosed space. Such required safe dispersal areas shall not be located less than 50 feet (15 240 mm) from the enclosed space. See Section 1028.5 for means of egress from safe dispersal areas.
Related Code Sections
1010.2.1 Means of Egress, Stadiums
Panic hardware is not required on gates surrounding stadiums where such gates are under constant immediate supervision while the public is present ...
Building Code 2018 of Illinois > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.2 Gates > 1010.2.1 Stadiums
1010.4.1 Means of Egress, Stadiums
Panic hardware is not required on gates surrounding stadiums where such gates are under constant immediate supervision while the public is present ...
Building Code 2021 of Illinois > 10 Means of Egress > 1010 Doors, Gates and Turnstiles > 1010.4 Gates > 1010.4.1 Stadiums
221.2.3.2.1 Scoping Requirements, Stadium-Style Movie Theaters
In stadium-style movie theaters, wheelchair spaces and companion seats shall be located on a riser or cross-aisle in the stadium section that either ...
2018 Illinois Accessibility Code > 2 Scoping Requirements > 221 Assembly Areas > 221.2 Wheelchair Spaces > 221.2.3 Lines of Sight and Dispersion > 221.2.3.2 Vertical Dispersion > 221.2.3.2.1 Stadium-Style Movie Theaters
907.2.1.2 Fire Protection and Life Safety Systems, Emergency Voice/Alarm Communication Captions
Stadiums, arenas and grandstands required to caption audible public announcements shall be in accordance with Section 907.5.2.2.4 ...
Building Code 2021 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.1 Group A > 907.2.1.2 Emergency Voice/Alarm Communication Captions
907.2.1.2 Fire Protection and Life Safety Systems, Emergency Voice/Alarm Communication Captions
Stadiums, arenas and grandstands required to caption audible public announcements shall be in accordance with Section 907.5.2.2.4 ...
Building Code 2018 of Illinois > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.1 Group A > 907.2.1.2 Emergency Voice/Alarm Communication Captions