A stack vent shall be installed for the waste stack. The size of the stack vent shall be not less than the size of the waste stack. Offsets shall be permitted in the stack vent and shall be located not less than 6 inches (152 mm) above the flood level of the highest fixture, and shall be in accordance with Section P3104.5. The stack vent shall be permitted to connect with other stack vents and vent stacks in accordance with Section P3113.3.

Related Code Sections

913.3 Vents, Stack Vent
A stack vent shall be provided for the waste stack. The size of the stack vent shall be not less than the size of the waste stack. Offsets shall ...
P3109.3 Vents, Stack Vent
A stack vent shall be installed for the waste stack. The size of the stack vent shall be not less than the size of the waste stack. Offsets shall ...
P3109.3 Vents, Stack Vent
A stack vent shall be installed for the waste stack. The size of the stack vent shall be not less than the size of the waste stack. Offsets shall ...
Section P3102 Vents, Vent Stacks and Stack Vents
The vent system serving each building drain shall have not less than one vent pipe that extends to the outdoors ...
Section P3102 Vents, Vent Stacks and Stack Vents
The vent system serving each building drain shall have not less than one vent pipe that extends to the outdoors ...