Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

§27-455 Sprinklers

NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 10 Public Garages > §27-455 Sprinklers
JUMP TO FULL CODE CHAPTER
(a) Automatic sprinkler protection complying with the construction provisions of article four of subchapter seventeen shall be provided as required for occupancy group B-1 or B-2 respectively, except that in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, storage of forty-five thousand gallons or less of product having a flash point over one hundred degrees F (tag open cup) in the cargo space of tank truck or other vehicles approved for such storage by the fire commissioner, pending delivery, shall not be deemed to require sprinkler protection.

(b) Smoke detection or thermostatic alarm with central office connection. A thermostatic alarm system or smoke detection system equipped with a central office connection complying with subchapter seventeen of this code, and reference standard RS-17-3 of the appendix to this code may be provided in lieu of the sprinkler system required under the preceding subdivision in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products having a flash point over one hundred degrees F (tag open cup) is twenty-two thousand five hundred gallons or more but not exceeding forty-five thousand gallons in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery.

(c) Portable fire fighting appliances, as the fire commissioner may direct, shall be provided in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products, having a flash point over one hundred degrees F (tag open cup), in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery, is less than twenty-two thousand five hundred gallons.

Related Code Sections


11.2.3.2.2 Design Approaches, Sprinklers
The densities and areas provided in Figure 11.2.3.1.1 shall be for use only with spray sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 11 Design Approaches > 11.2 Occupancy Hazard Fire Control Approach for Spray Sprinklers > 11.2.3 Water Demand Requirements — Hydraulic Calculation Methods > 11.2.3.2 Density/Area Method > 11.2.3.2.2 Sprinklers
6.2 System Components and Hardware, Sprinklers
Only new sprinklers shall be installed. When ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 6 System Components and Hardware > 6.2 Sprinklers
7.2.2 System Requirements, Sprinklers
The following sprinkler orientations and arrangements shall be permitted for dry pipe systems: Upright sprinklers *Listed dry sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.2* Dry Pipe Systems > 7.2.2 Sprinklers
7.3.2.5 System Requirements, Sprinklers
The following sprinkler orientations and arrangements shall be permitted for preaction systems: Upright sprinklers *Listed dry sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.3 Preaction Systems and Deluge Systems > 7.3.2 Preaction Systems > 7.3.2.5 Sprinklers
7.4.2.4 System Requirements, Sprinklers
The following types of sprinklers and arrangements shall be permitted for combined dry pipe and preaction systems: Upright sprinklers *Listed ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.4 Combined Dry Pipe and Preaction Systems for Piers, Terminals, and Wharves > 7.4.2* General > 7.4.2.4 Sprinklers
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING