§27-455 Sprinklers
JUMP TO FULL CODE CHAPTER
(a) Automatic sprinkler protection complying with the construction provisions of article four of subchapter seventeen shall be provided as required for occupancy group B-1 or B-2 respectively, except that in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, storage of forty-five thousand gallons or less of product having a flash point over one hundred degrees F (tag open cup) in the cargo space of tank truck or other vehicles approved for such storage by the fire commissioner, pending delivery, shall not be deemed to require sprinkler protection.
(b) Smoke detection or thermostatic alarm with central office connection. A thermostatic alarm system or smoke detection system equipped with a central office connection complying with subchapter seventeen of this code, and reference standard RS-17-3 of the appendix to this code may be provided in lieu of the sprinkler system required under the preceding subdivision in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products having a flash point over one hundred degrees F (tag open cup) is twenty-two thousand five hundred gallons or more but not exceeding forty-five thousand gallons in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery.
(c) Portable fire fighting appliances, as the fire commissioner may direct, shall be provided in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products, having a flash point over one hundred degrees F (tag open cup), in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery, is less than twenty-two thousand five hundred gallons.
(b) Smoke detection or thermostatic alarm with central office connection. A thermostatic alarm system or smoke detection system equipped with a central office connection complying with subchapter seventeen of this code, and reference standard RS-17-3 of the appendix to this code may be provided in lieu of the sprinkler system required under the preceding subdivision in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products having a flash point over one hundred degrees F (tag open cup) is twenty-two thousand five hundred gallons or more but not exceeding forty-five thousand gallons in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery.
(c) Portable fire fighting appliances, as the fire commissioner may direct, shall be provided in existing buildings lawfully occupied as garages prior to December sixth, nineteen hundred sixty-eight, when the storage of fuel oils or other products, having a flash point over one hundred degrees F (tag open cup), in the cargo space of tank trucks or other vehicles approved for such storage by the fire commissioner, pending delivery, is less than twenty-two thousand five hundred gallons.
Related Code Sections
11.2.3.2.2 Design Approaches, Sprinklers
The densities and areas provided in Figure 11.2.3.1.1 shall be for use only with spray sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 11 Design Approaches > 11.2 Occupancy Hazard Fire Control Approach for Spray Sprinklers > 11.2.3 Water Demand Requirements — Hydraulic Calculation Methods > 11.2.3.2 Density/Area Method > 11.2.3.2.2 Sprinklers
6.2 System Components and Hardware, Sprinklers
Only new sprinklers shall be installed. When ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 6 System Components and Hardware > 6.2 Sprinklers
7.2.2 System Requirements, Sprinklers
The following sprinkler orientations and arrangements shall be permitted for dry pipe systems: Upright sprinklers *Listed dry sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.2* Dry Pipe Systems > 7.2.2 Sprinklers
7.3.2.5 System Requirements, Sprinklers
The following sprinkler orientations and arrangements shall be permitted for preaction systems: Upright sprinklers *Listed dry sprinklers ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.3 Preaction Systems and Deluge Systems > 7.3.2 Preaction Systems > 7.3.2.5 Sprinklers
7.4.2.4 System Requirements, Sprinklers
The following types of sprinklers and arrangements shall be permitted for combined dry pipe and preaction systems: Upright sprinklers *Listed ...
Standard for the Installation of Sprinkler Systems 2016 of New York City > 7 System Requirements > 7.4 Combined Dry Pipe and Preaction Systems for Piers, Terminals, and Wharves > 7.4.2* General > 7.4.2.4 Sprinklers