[F] 416.3 Spraying Spaces
JUMP TO FULL CODE CHAPTER
Spraying spaces shall be ventilated with an exhaust system to prevent the accumulation of flammable mist or vapors in accordance with the International Mechanical Code. Where such spaces are not separately enclosed, noncombustible spray curtains shall be provided to restrict the spread of flammable vapors.
The interior surfaces of spraying spaces shall be smooth; shall be so constructed to permit the free passage of exhaust air from all parts of the interior and to facilitate washing and cleaning; and shall be so designed to confine residues within the spraying space. Aluminum shall not be used.
Related Code Sections
416.3 Special Detailed Requirements Based on Occupancy and Use, Spraying Spaces
Spraying spaces shall be ventilated with an exhaust system to prevent the accumulation of flammable mist or vapors in accordance ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 416 Spray Application of Flammable Finishes > 416.3 Spraying Spaces
416.3 Special Detailed Requirements Based on Occupancy and Use, Spraying Spaces
Spraying spaces shall be ventilated with an exhaust system to prevent the accumulation of flammable mist or vapors in accordance ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 416 Spray Application of Flammable Finishes > 416.3 Spraying Spaces
10.3.4.1 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers, Maximum Distance Between Sprinklers
Where sidewall spray sprinklers are installed along the length of a single wall of rooms or bays, they shall be spaced in accordance ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 10 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers > 10.3 Sidewall Standard Spray Sprinklers > 10.3.4 Sprinkler Spacing (Standard Sidewall Spray Sprinklers) > 10.3.4.1 Maximum Distance Between Sprinklers
10.3.4.2 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers, Maximum Distance From Walls
The distance from sprinklers to the end walls shall not exceed one-half of the allowable distance permitted between sprinklers as indicated in Table ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 10 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers > 10.3 Sidewall Standard Spray Sprinklers > 10.3.4 Sprinkler Spacing (Standard Sidewall Spray Sprinklers) > 10.3.4.2 Maximum Distance From Walls
10.3.4.3 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers, Minimum Distance From Walls
Sprinklers shall be located a minimum of 4 in. (100 mm) from an end wall ...
Standard for the Installation of Sprinkler Systems 2019 of Illinois > 10 Installation Requirements for Standard Pendent, Upright, and Sidewall Spray Sprinklers > 10.3 Sidewall Standard Spray Sprinklers > 10.3.4 Sprinkler Spacing (Standard Sidewall Spray Sprinklers) > 10.3.4.3 Minimum Distance From Walls