// CODE SNIPPET
Section 423 Specialty Plumbing Fixtures
Go To Full Code Chapter
423.1 Water Connections
Baptisteries, ornamental and lily pools, aquariums, ornamental fountain basins, swimming pools, and similar constructions, where provided with water supplies, shall be protected against backflow in accordance with Section 608.
423.2 Approval
Specialties requiring water and waste connections shall be submitted for approval.
423.3 Footbaths and Pedicure Baths
The water supplied to specialty plumbing fixtures, such as pedicure chairs having an integral foot bathtub and footbaths, shall be limited to not greater than 120°F (49°C) by a water-temperature-limiting device that conforms to ASSE 1070/ASME A112.1070/CSA B125.70 or by a water heater complying with ASSE 1082.