Restaurant kitchen and other special use sinks shall be permitted to be made of approved-type bonderized and galvanized sheet steel of not less than No. 16 U.S. gauge (0.0635 inches) (1.6 mm). Sheet-metal plumbing fixtures shall be adequately designed, constructed, and braced in an approved manner to accomplish their intended purpose.

Related Code Sections

406.2 Plumbing Fixtures and Fixture Fittings, Special Use Sinks
Restaurant kitchen and other special use sinks shall be permitted to be made of approved-type bonderized and galvanized sheet steel of not less than ...
1109.3 Accessibility, Sinks
Where sinks are provided, at least 5 percent but not less than one provided in accessible spaces shall be accessible. Exception: Mop or service ...
420.0 Plumbing Fixtures and Fixture Fittings, Sinks
Sinks shall comply with ASME A112.19.1/CSA B45.2, ASME A112.19.2/CSA B45.1, ASME A112.19.3/CSA B45.4, CSA B45.5/IAPMO Z124, CSA B45.8/IAPMO Z403 ...
Section P2714 Plumbing Fixtures, Sinks
Sinks shall be provided with waste outlets not less than 11/2 inches (38 mm) in diameter. A strainer, crossbar or other device shall be provided ...