// CODE SNIPPET
63-23 Special Transparency Requirements
JUMP TO FULL CODE CHAPTER
For all developments containing FRESH food stores, or ground floor level enlargements containing FRESH food stores, the following provisions shall apply. For the portion of the building containing a FRESH food store, the ground floor level of the street wall fronting upon a primary street frontage shall be glazed in accordance with the provisions of Section 37-34 (Minimum Transparency Requirements).
Furthermore, for FRESH food stores with frontage on two or more streets, the Chairperson of the City Planning Commission may certify that the glazing requirements of this Section shall only be applicable to the street wall fronting upon the principal street, as determined by the Chairperson.
In addition, the Chairperson may, by certification, allow a reduction in the glazing requirements of this Section, provided that the Chairperson finds that such building is a recipient of public funding. For the purposes of this Section, defined terms shall include those in Sections 12-10, 23-911 and 37-311.
Related Code Sections
*1403.8.1 Exterior Walls, Exterior Wall Envelope
areas of special flood hazard and shaded X-Zones where flood resistant glazing is proposed and ground floor transparency is required by the New York City ...
NYC Building Code 2014 > 14 Exterior Walls > 1403 Performance Requirements > *1403.8 Bird Friendly Materials > *1403.8.1 Exterior Wall Envelope
*1403.8.1 Exterior Walls, Exterior Wall Envelope
areas of special flood hazard and shaded X-Zones where flood resistant glazing is proposed and ground floor transparency is required by the New York ...
NYC Building Code 2022 > 14 Exterior Walls > 1403 Performance Requirements > *1403.8 Bird Friendly Materials > *1403.8.1 Exterior Wall Envelope
8.6.11.4.1 General Requirements,
The cleaning of the exterior of transparent car enclosures or transparent hoistway enclosures from inside the hoistway shall be performed only ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.6 Maintenance, Repair, Replacement, and Testing > 8.6.11 Special Provisions > 8.6.11.4 Cleaning of a Car and Hoistway Transparent Enclosure > 8.6.11.4.1
8.6.11.4.5 General Requirements,
A record of authorized personnel trained as specified in 8.6.11.4.4 shall be kept on the premises where the elevator is located and shall be available ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.6 Maintenance, Repair, Replacement, and Testing > 8.6.11 Special Provisions > 8.6.11.4 Cleaning of a Car and Hoistway Transparent Enclosure > 8.6.11.4.5
8.6.11.4 General Requirements, Cleaning of a Car and Hoistway Transparent Enclosure
The cleaning of the exterior of transparent car enclosures or transparent hoistway enclosures from inside the hoistway shall be performed only ...
Safety Code for Elevators and Escalators 2013 of New York City > 8 General Requirements > 8.6 Maintenance, Repair, Replacement, and Testing > 8.6.11 Special Provisions > 8.6.11.4 Cleaning of a Car and Hoistway Transparent Enclosure