Buildings located on zoning lots, or portions of zoning lots within the Theater Subdistrict Core or the Eighth Avenue Corridor, shall comply with the regulations of this Section. The height of all buildings or other structures shall be measured from curb level.
81-751 Special Street Wall and Setback Regulations Within the Theater Subdistrict Core
Buildings located on zoning lots between 43rd and 50th Streets with street frontage on Seventh Avenue and/or Broadway, or located partially within the Theater Subdistrict Core and partially within the Eighth Avenue Corridor shall comply with the requirements of this Section and, in all other respects related to height and setback, with the provisions of Sections 81-25 (General Provisions Relating to Height and Setback of Buildings), and either Section 81-26 (Height and Setback Regulations - Daylight Compensation) or 81-27 (Alternate Height and Setback Regulations - Daylight Evaluation). The street wall location rules of Section 81-43 shall also apply, except as modified in this Section.
With the exception of signs and parapets not exceeding four feet in height, no obstructions are permitted to penetrate the mandatory street wall height limits or setback requirements for zoning lots between 43rd and 50th Streets with street frontage on Seventh Avenue and/or Broadway set forth in this Section.
For the purposes of this Section, signs are permitted as exceptions to the special street wall and setback requirements contained herein, except that above the top of a street wall before setback required under this Section, no sign may be located closer than six feet to the Seventh Avenue or Broadway street wall before setback. Signs located below the top of a required street wall before setback, as defined in this Section, may project across a street line up to 10 feet. Marquees are not subject to the requirements of this Section.
  1. With the exception of buildings located on zoning lots between Seventh Avenue and Broadway, buildings located on zoning lots between 43rd and 50th Streets with street frontage on Seventh Avenue or Broadway shall meet the following requirements:
    1. The street walls of any building shall have a minimum street wall height before setback of 50 feet above curb level and a maximum street wall height before setback of 60 feet above curb level on all street frontages, except that:
      1. if the zoning lot contains a complete wide street block frontage, wide street street walls within 25 feet of the street line of a narrow street and narrow street street walls shall have a minimum street wall height before setback of 30 feet above curb level; and/or
      2. if the zoning lot contains a theater listed in the table in Section 81-742 (Listed theaters) and the theater is retained as part of a development or enlargement, the maximum street wall height above curb level before setback of a narrow street street wall which is a reconstruction or replacement of an existing narrow street street wall of the theater shall be equal to the height above curb level of that existing theater street wall and the same maximum street wall height above curb level shall apply only for the width of that existing theater street wall.
    2. Above the required street wall height before setback, the street wall of any building shall be set back at least 15 feet along all narrow street frontages of the zoning lot.
    3. For zoning lots greater than 15,000 square feet in area:
      1. Above the required street wall height before setback, the street wall of any building shall be set back at least 50 feet along the Seventh Avenue or Broadway street frontage of the zoning lot.
      2. Alternatively, above the required street wall height before setback, the street wall shall be set back at least 60 feet along the Seventh Avenue or Broadway street frontage of the zoning lot, except that a portion of the building at least 50 feet from the street line of any narrow street and with aggregate area per floor not exceeding 10 square feet for each linear foot of zoning lot street frontage on Seventh Avenue or Broadway may extend forward of the 60 foot setback line, provided that no portion is closer than 35 feet to the Seventh Avenue or Broadway street line.
      3. Alternatively, if the building contains a "listed theater" designated pursuant to Section 81-742 and if any portion of the theater is within 100 feet of the street line of Seventh Avenue or Broadway, above the required street wall height before setback the street wall shall be set back at least 60 feet along the Seventh Avenue or Broadway street frontage of the zoning lot, except that a portion of the building with aggregate area per floor not exceeding the lesser of 4,500 square feet or 30 square feet for each linear foot of zoning lot street frontage on Seventh Avenue or Broadway, may extend forward of the 60 foot setback line, provided that no portion is closer than 20 feet to the Seventh Avenue or Broadway street line, 15 feet to the street line of the narrow street on which the theater has frontage and 50 feet to any other narrow street street line.

        In addition, one or more signs affixed to any such building may project up to 10 feet across the street line and rise to a height of 120 feet above curb level. Balconies and terraces, including railings or parapets, may be located within the required setback area behind such signs. For the purposes of applying the definition of floor area in Section 12-10, signs projecting across the street line shall not constitute an enclosure, and the requirements of Section 32-41 (Enclosure Within Buildings) shall not apply to such balconies or terraces, provided that a portion of any such balcony or terrace is used for an entertainment-related use listed in Section 81-725 (Entertainment-related uses) or an accessory use.
    4. For zoning lots 15,000 square feet in area or less, above the required street wall height before setback, the street wall of any building shall be set back at least 35 feet along the Seventh Avenue or Broadway street frontage of the zoning lot.
    5. Above the required street wall height before setback, a portion of any such building up to a height of 120 feet above curb level may occupy area forward of the setbacks required in paragraphs (a)(3) or (a)(4) of this Section but not closer than 20 feet to the Seventh Avenue or Broadway street line, provided that:
      1. 90 percent of any narrow street street wall, higher than 60 feet above curb level and forward of the setbacks required in paragraphs (a)(3) or (a)(4) of this Section is covered with illuminated signs.
      2. In addition, 90 percent or 6,000 square feet, whichever is less, of any Seventh Avenue or Broadway street wall higher than 60 feet above curb level and forward of the setbacks required in paragraphs (a)(3) or (a)(4) of this Section is covered with illuminated signs.
        For the purposes of this Section, a portion of a street wall shall be deemed to be covered with an illuminated sign if such sign obscures that portion of the street wall from view at street level at a point perpendicular in plan to the sign and 60 feet from the street line of the narrow street for paragraph (a)(5)(i) of this Section, and of Seventh Avenue or Broadway for paragraph (a)(5)(ii)

        Neither temporary certificates of occupancy for floor area of the development or enlargement comprising, in aggregate, more than 50 percent of the total floor area of the development or enlargement, nor a first permanent certificate of occupancy for the development or enlargement, shall be issued by the Department of Buildings until all of the requirements as set forth in this Section at the time of issuance of such certificates of occupancy have been met and all illuminated signs required under this Section have been installed and put in operation.
  2. The street wall of any building on a zoning lot between 43rd and 50th Streets and between Seventh Avenue and Broadway shall have a minimum street wall height of 50 feet on all street frontages.
  3. For zoning lots located partially within the Theater Subdistrict Core and partially within the Eighth Avenue Corridor, the street wall of any building or portion of a building within the Theater Subdistrict Core shall have a minimum street wall height of 50 feet or the height of the building, whichever is less, and a maximum street wall height of 60 feet within 15 feet of the narrow street street line.
See More

Related Code Sections

*3113.12 Special Construction, Setback
No part of a small wind turbine or small wind turbine tower shall be located within a horizontal distance of a property line that is equal or less ...
*3114.12 Special Construction, Setback
No part of a large wind turbine or large wind turbine tower shall be located within a horizontal distance of a property line that is equal or less ...
*3114.12 Special Construction, Setback
No part of a large wind turbine or large wind turbine tower shall be located within a horizontal distance of a property line that is equal or less ...
*3115.12 Special Construction, Setback
No part of a small wind turbine or small wind turbine tower shall be located within a horizontal distance of a property line that is equal or less ...
1114.1.3 Storm Drainage, Minimum Setbacks
On-site stormwater disposal systems shall be located at least 5 feet (1524 mm) from all lot lines and 10 feet (3048 mm) from all foundations or walls ...