• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

903.3.1.5 Special Sprinkler Design Criteria

Minnesota Building Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.5 Special Sprinkler Design Criteria
JUMP TO FULL CODE CHAPTER
When fire sprinkler systems are required in areas containing the following uses, they shall be designed and installed to have a sprinkler density of not less than that required for an Ordinary Hazard Group 2 use:
  1. Chemistry labs; or
  2. Wrestling rooms or gymnastic rooms.

Related Code Sections


903.3.1.5 Fire Protection and Life Safety Systems, Special Sprinkler Design Criteria
When fire sprinkler systems are required in areas containing the following uses, they shall be designed and installed to have a sprinkler density ...
2020 Minnesota State Fire Code > 9 Fire Protection and Life Safety Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.5 Special Sprinkler Design Criteria
903.3.1.5 Fire Protection Systems, Special Sprinkler Design Criteria
When fire sprinkler systems are required in areas containing the following uses, they shall be designed and installed to have a sprinkler density ...
Minnesota Building Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.5 Special Sprinkler Design Criteria
903.3.1.5 Fire Protection Systems, Special Sprinkler Design Criteria
When fire sprinkler systems are required in areas containing the following uses, they shall be designed and installed to have a sprinkler density ...
Minnesota Fire Code 2015 > 9 Fire Protection Systems > 903 Automatic Sprinkler Systems > 903.3 Installation Requirements > 903.3.1 Standards > 903.3.1.5 Special Sprinkler Design Criteria
20.3.4 Special Designs of Storage Protection,
A wet pipe system designed to meet two separate design points — 0.45 gpm/ft2 (18.3 mm/min) density over 2000 ft2 (186 m2) and 0.55 gpm/ft2 (22.4 mm ...
Standard for the Installation of Sprinkler Systems 2016 of Minnesota > 20 Special Designs of Storage Protection > 20.3* Sprinkler Design Criteria for Storage and Display of Class I Through Class IV Commodities, Cartoned Nonexpanded Group A Plastics and Nonexpanded Exposed Group A Plastics in Retail Stores > 20.3.4
Help Contact Us Privacy Terms
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING