• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

101-61 Special Sign Regulations for the Fulton Mall Subdistrict

NYC Zoning Resolution > X - Special Purpose Districts > 1 Special Downtown Brooklyn District (dB) > 101-60 Fulton Mall Subdistrict > 101-61 Special Sign Regulations for the Fulton Mall Subdistrict
JUMP TO FULL CODE CHAPTER
Any erection of a new sign, or alteration (including a change in graphic representation on an existing sign), reconstruction or replacement of an existing sign, shall be subject to the special sign regulations of this Section, inclusive.

101-611 Area of Permitted Signs

Except for projecting signs that comply with the provisions of Section 101-131 (Permitted projection), all permitted signs in the Fulton Mall Subdistrict shall be subject to the applicable provisions of Section 32-64 (Surface Area and Illumination Provisions), Section 101-612 (Sign band) and this Section.

101-612 Sign Band

  1. Sign located within the sign band

    A commercial establishment located on the ground floor of a building may have one sign located on each street frontage within a sign band as defined in this Section.

    The sign band shall have a lower limit of 10 feet above curb level and an upper limit coincident with the bottom of the lowest window sill on the second floor of a building, but in no event more than 15 feet above curb level. A sign located within the sign band may be applied directly to the surface of a building or to a sign board affixed to the surface of a building. If a sign board is employed, such sign board shall be entirely within the sign band, shall be mounted horizontally, shall have a uniform color over its entire surface excluding perimeter frame or trim and shall extend the full length of the street wall of the establishment to which it is accessory, except that such sign board may be interrupted by vertical architectural elements such as columns, pilasters or other integral architectural elements. Any background material shall be considered as a sign board, unless it extends the full length of the street wall of a building (or that portion of a building occupied by the establishment) and the full height of the building up to the topmost cornice. On corner lots, a sign or sign boards shall be the same vertical dimension and shall be mounted at the same height above the curb level on both street frontages.

    If more than one commercial establishment is located on the ground floor of a building, the signs located within the sign band accessory to each such establishment shall consist of letters and symbols of approximately the same size for each establishment, either applied directly to the surface of the building or to a common sign board affixed to the surface of a building.

    As of March 16, 1978, the owner or lessee of a building with more than one ground floor establishment shall be responsible (unless the sign is applied directly to the surface of the building) for specifying the requirements of a common sign board, which shall include, but are not limited to, vertical dimension, mounting height, background color, material, whether illuminated and method of illumination (if applicable) which shall be the same for each establishment and shall be adhered to by each establishment employing a sign board.

    A sign accessory to uses on the upper floors of a building may be located within the sign band when it directs attention to a ground floor entrance of an establishment located on the upper floors of a building.
  2. Signs located below the sign band

    Signs accessory to commercial establishments located on the ground floor of a building may be located between curb level and 10 feet above curb level. Signs in show windows, on doors, or on transoms above doors, shall not occupy more than 20 percent of the total area of such show windows, doors or transoms above doors in which they are displayed, and are limited to writing (including letter, word or numeral) not more than eight inches high. Such sign shall be applied directly to show windows, doors or transoms above doors, without background, or to a transparent panel hung behind the plane of the show window surface, door or transom above a door. Non-flashing illuminated signs (such as neon, etc.) shall be permitted providing that such signs are essentially transparent, i.e., without background or enclosure.

    Incidental signs, identifying store name, address and hours of operation shall not exceed 10 square feet (including background) for an individual sign and shall not exceed, in aggregate (square feet), one-fifth the street frontage of the establishment but in no event more than 50 square feet for interior or through lots or 50 square feet on each frontage for corner lots.

    An establishment located above the ground floor of a building that has an entrance on the ground floor may have one sign directing attention to the entrance.
  3. Signs located above the sign band

    Signs accessory to commercial establishments which occupy space above the ground floor of a building may be located between 20 feet and 40 feet above curb level. Such establishments may have signs in windows provided that such sign does not occupy more than 30 percent of the window to which it is applied, that the remainder of the window is transparent, and that all such signs for an establishment have similar size and style of writing, pictorial representation, emblem or any other figure of similar character. Commercial establishments which occupy space above the ground floor may have one sign located above the sign band which is applied directly to the surface of a building or to a sign board affixed to the surface of a building. If a sign board is employed, such sign board shall be mounted horizontally, shall have a uniform color over its entire surface, excluding perimeter frame and trim, and shall not be located between windows. The total surface area of all signs located above the sign band shall not exceed three times the street frontage of the zoning lot (in feet) but in no event more than 200 square feet on each frontage.

    No sign or sign board shall extend above the parapet wall or shall obscure any cornice or window.

101-613 Special Sign Content Regulations

Except as further defined by the regulations of the Special Downtown Brooklyn District, permitted signs are limited to the following message:
store name;
symbol or logo;
address;
date of establishment; and
description of product or service offered.

101-614 Sign Illuminations

Signs may be illuminated by either:
  1. internal illumination; or
  2. an external source that shall be so arranged that it projects no more than 12 inches from the sign it illuminates, and so that no direct rays of light are projected into adjoining buildings or the street. No flashing signs are permitted nor are flashing or rotating light sources except illuminated signs that indicate the time, temperature, weather or other similar information, pursuant to the definition of flashing sign in Section 12-10.

101-615 Temporary Signs

Temporary signs relating to sales or events of limited duration not to exceed 45 days may be displayed in a show window of a building. Such signs must be removed after the last day of the sale or event to which they pertain. Temporary signs shall not occupy more than 20 percent of the surface area of the window in which they are displayed.

101-616 Removal of Existing Signs With Change of Use

When a change of use or occupancy occurs within the Fulton Mall Subdistrict, all signs pertaining to the previous use or occupancy shall be removed within 45 days of the date such change takes place.

101-617 "For Sale" or "For Rent" Signs

"For sale" or "for rent" signs, with an area not exceeding 12 square feet, are permitted.

101-618 Termination of Certain Non-Conforming Signs

In the Fulton Mall Subdistrict, Section 52-80 (REGULATIONS APPLYING TO NON-CONFORMING SIGNS) shall not apply. In lieu thereof, certain non-conforming signs may be continued until June 30, 1980, providing that after that date such non-conforming signs shall terminate and shall be removed in their entirety, including any supporting structure, frame or device. Such signs shall include:
advertising signs;

flashing signs;

signs located more than 40 feet above curb level;

roof signs;

signs extending above a parapet;

signs obscuring cornices and windows;

double or multi-faced signs; and

signs that project across a street line more than 12 inches.
Any sign, as of January 1, 1978, that forms an integral part of the surface of a building or other structure (such as a sign carved in stone, cast in metal or molded in terra cotta on a building whose facade is of such material) shall not be subject to the provisions of this Section.

Related Code Sections


§27-521.16 Special Uses and Occupancies, Signs
Malls shall be provided with all signs required by articles seven and nine of subchapter six of this chapter, regardless of occupant load of the mall ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 22 Malls > §27-521.16 Signs
402.16 Special Detailed Requirements Based on Use and Occupancy, Plastic Signs
Plastic signs affixed to the storefront of any tenant space facing the mall shall be limited as specified in Sections 402.16.1 through 402.16.5 ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 402 Covered Mall and Open Mall Buildings > 402.16 Plastic Signs
Section 402 Special Detailed Requirements Based on Use and Occupancy, Covered Mall and Open Mall Buildings
the mall. Plastic signs shall be not greater 30 than ...
NYC Building Code 2022 > 4 Special Detailed Requirements Based on Use and Occupancy > 402 Covered Mall and Open Mall Buildings
3202.2.1.8 Encroachments Into the Public Right-Of-Way, Projecting Signs
permanent projecting sign shall be erected on any building on: Fulton Street between Flatbush Avenue and Joralemon Street and Willoughby Street ...
NYC Building Code 2014 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.1 Encroachments Subject to the Area Limitations > 3202.2.1.8 Projecting Signs
3202.2.1.8 Encroachments Into the Public Right-Of-Way, Projecting Signs
permanent projecting sign shall be erected on any building on: Fulton Street between Flatbush Avenue and Joralemon Street and Willoughby Street ...
NYC Building Code 2008 > 32 Encroachments Into the Public Right-Of-Way > 3202 Encroachments > 3202.2 Encroachments Above Grade > 3202.2.1 Encroachments Subject to the Area Limitations > 3202.2.1.8 Projecting Signs
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING