• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

126-30 Special Off-Street Parking and Loading Regulations

NYC Zoning Resolution > XII Special Purpose Districts > 6 - Special College Point District (CP) > 126-30 Special Off-Street Parking and Loading Regulations
JUMP TO FULL CODE CHAPTER

The off-street parking and loading regulations of the underlying district are modified as set forth in this Section, inclusive.

126-31 Parking Regulations

(a)        Accessory off-street parking shall not be permitted within a required front yard.

(b)        The provisions of Section 44-21 (General Provisions) pertaining to accessory off-street parking spaces for commercial uses shall be modified as follows:


Hotels, for the floor area used for sleeping accommodations, shall be required to provide one parking space per two guest rooms or suites and, for the floor area used for meeting halls, auditoriums, eating or drinking places, wedding chapels or banquet halls, or radio or television studios, shall be required to provide one parking space per four persons-rated capacity

Places of Assembly, for uses in parking requirement category D in Use Group 6, 8, 9, 10 or 12, or when permitted by special permit, shall be required to provide one parking space per four persons-rated capacity

(c)        For commercial uses within the commercial areas identified on the Special College Point District Map, the parking requirements of a C4-1 District shall apply.

(d)        Section 37-90 (PARKING LOTS), inclusive, shall apply to all open parking areas accessory to manufacturing uses listed in Use Group 17. Perimeter landscaping, required pursuant to Section 37-921, may overlap with required yards, pursuant to Section 126-231.

(e)        The provisions of Section 44-23 (Waiver of Requirements for Spaces Below Minimum Number) shall only apply to zoning lots existing both on July 29, 2009, and on the date of application for a building permit.

126-32 Loading Regulations

(a)        Off-street loading berths shall not be permitted between a street wall and a street line. However, the City Planning Commission may authorize off-street loading berths located between a street wall and a street line, provided that the Commission finds that such loading berths can not be located elsewhere on the zoning lot and that such loading berths shall be enclosed or screened to the greatest extent practicable.

(b)        All open off-street loading berths shall be screened from all adjoining zoning lots pursuant to the standards of Section 44-585 (Screening).

126-33 Curb Cut Restrictions on 15th Avenue

Within the Special College Point District, curb cuts shall be prohibited on 15th Avenue.

However, where permitted or required accessory off-street parking and loading requirements apply in a location where such curb cuts are prohibited, a curb cut may be allowed, provided that the City Planning Commission certifies to the Commissioner of Buildings that such zoning lot has access to the street only through such prohibited location and that such curb cut shall be no greater than 20 feet in width.

An application to the City Planning Commission for certification respecting such curb cut shall be accompanied by a site plan drawn to a scale of at least one-sixteenth inch to a foot, showing the size and location of the proposed curb cut.

Related Code Sections


Article 13 Special Uses and Occupancies, Open Parking Lots
an off-street parking facility is constructed in connection with the construction of a new building, or whenever such parking facility falls within ...
NYC 1968 Code (Vol I) > 7 Special Uses and Occupancies > 13 Open Parking Lots
1106.7.4 Accessibility, Mechanical Access Parking Garages
Mechanical access parking garages shall provide at least one passenger loading zone in compliance with Section 1106.7 at vehicle drop-off and vehicle ...
NYC Building Code 2014 > 11 Accessibility > 1106 Parking and Passenger Loading Facilities > 1106.7 Passenger Loading Zones > 1106.7.4 Mechanical Access Parking Garages
§27-559 Loads, Columns in Parking Areas
Unless specially protected, columns in parking areas subject to impact of moving vehicles shall be designed to resist the lateral load due to impact ...
NYC 1968 Code (Vol I) > 9 Loads > 3 Live Loads > §27-559 Columns in Parking Areas
*§28-504.1.3 Miscellaneous Provisions, Exceptions
no-cost off-street bicycle parking or sufficient secure alternate indoor no-cost bicycle parking available on the premises or within four blocks or 1,000 ...
NYC General Admin. Provisions 2014 > 5 Miscellaneous Provisions > 504 *Bicycle Access to Buildings > *§28-504.1 Bicycle Access to Certain Office Buildings > *§28-504.1.3 Exceptions
Reference Standard 7 Special Uses and Occupancies [PDF] (page 1)
between Washington Square north and 110th Street, 34th Street between Park Avenue and 7th Avenue, Madison Avenue between 23d Street and 96th Street, 57th ...
NYC 1968 Code (Vol II) [PDF] > Reference Standard 7 Special Uses and Occupancies
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE