A-703.1 Special Occupancy Requirement for Structures in Group E Occupancy
JUMP TO FULL CODE CHAPTER
No structure in Group E occupancy, the Educational occupancy, as defined in Subcode "B" of Title 4 owned or operated by an entity to which the City provides substantial funding, shall be occupied unless a current special certificate of inspection has been issued in connection with such structure.
Exception: Day care facilities that are not part of a school are not regulated under this subsection, except that day care facilities that are not part of a school, but at which thirteen or more children are cared for must comply with the certification requirements pertaining to water quality set forth in subsection A-703.2.4.B.
Related Code Sections
A-703.1 Certificates and Approvals, Special Occupancy Requirement for Structures in Group E Occupancy
No structure in Group E occupancy, the Educational occupancy, as defined in Subcode "B" of Title 4 owned or operated by an entity to which the City ...
Philadelphia Administrative Code > 7 Certificates and Approvals > A-703 Special Certificate of Inspection > A-703.1 Special Occupancy Requirement for Structures in Group E Occupancy
423.4 Special Detailed Requirements Based on Occupancy and Use, Group E Occupancies
is being added on an existing Group E site, and where the new building is not of sufficient size to accommodate the required occupant capacity ...
Philadelphia Building Code > 4 Special Detailed Requirements Based on Occupancy and Use > 423 Storm Shelters > 423.4 Group E Occupancies
907.2.3 Fire Protection and Life Safety Systems, Group E
the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E occupancies. Where automatic sprinkler ...
Philadelphia Fire Code > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.3 Group E
907.2.3 Fire Protection and Life Safety Systems, Group E
the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E occupancies. Where automatic sprinkler ...
Philadelphia Building Code > 9 Fire Protection and Life Safety Systems > 907 Fire Alarm and Detection Systems > 907.2 Where Required—New Buildings and Structures > 907.2.3 Group E
(E) Special Equipment, Grouping
The PV system disconnecting means shall be grouped with other disconnecting means for the system in accordance with 690.13(D). A PV disconnecting ...
National Electrical Code 2014 of Philadelphia > 6 Special Equipment > 690 Solar Photovoltaic (PV) Systems > 690.13 Building or Other Structure Supplied by a Photovoltaic System > (E) Grouping