1910.66(g)(4) Special Inspection of Governors and Secondary Brakes
Go To Full Code Chapter
1910.66(g)(4)(i)
Governors and secondary brakes shall be inspected and tested at intervals specified by the manufacturer/supplier but not to exceed every 12 months.
1910.66(g)(4)(iii)
The results of the inspection and test shall confirm that the secondary brake is functioning properly.
1910.66(g)(4)(iv)
If any hoisting machine or initiating device for the secondary brake system is removed from the equipment for testing, all reinstalled and directly related components shall be reinspected prior to returning the equipment installation to service.
1910.66(g)(4)(v)
Inspection of governors and secondary brakes shall be performed by a competent person.
1910.66(g)(4)(vi)
The secondary brake governor and actuation device shall be tested before each day's use. Where testing is not feasible, a visual inspection of the brake shall be made instead to ensure that it is free to operate.
1910.66(g)(4)(ii)
The results of the inspection and test shall confirm that the initiating device for the secondary braking system operates at the proper overspeed.
Upcodes Diagrams
Related Code Sections
1910.66(g)(4) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms, Special Inspection of Governors and Secondary Brakes
Governors and secondary brakes shall be inspected and tested at intervals specified by the manufacturer/supplier but not to exceed every 12 months ...
1910.66(g)(4)(iv) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
If any hoisting machine or initiating device for the secondary brake system is removed from the equipment for testing, all reinstalled and directly ...
1910.266(f)(7) Special Industries, Brakes
September 8, 1995 shall also be equipped with: back-up or secondary brakes that are capable of stopping the machine regardless of the direction of travel ...
1910.66(g) Powered Platforms, Manlifts, and Vehicle-Mounted Work Platforms,
Governors and secondary brakes shall be inspected ...
1910.262(y)(1)(iii) Special Industries, Brakes
Each extractor shall be equipped with a mechanically or electrically operated brake to quickly stop the basket when the power driving the basket ...