• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1704.10.1 Special Inspection for Wall Panels, Curtain Walls and Veneers

NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.10 Wall Panels, Curtain Walls and Veneers > 1704.10.1 Special Inspection for Wall Panels, Curtain Walls and Veneers
JUMP TO FULL CODE CHAPTER
The special inspector shall become familiar with and retain a copy of the construction documents, shop drawings, instructions for the sequence of component installation, samples and/or mock-ups, if supplied. The special inspector shall field check the site conditions at the time the structure is prepared for component installation to verify: that the supporting structure is properly aligned and within deign tolerances, that required inserts are properly installed, that framing components are properly sized, aligned, and without structural defects or weakness, that anchors are properly placed, welded, bolted and finished as applicable, that weeps, flashings and tubes are in place and properly drained, that joinery and end dams are properly sealed per plans, that sealing materials with sufficient elongation capability are provided, that gaskets meet specifications, that materials are installed to compensate for horizontal and vertical movement in accordance with the design and the manufacturers guidelines and that any other observations pertinent to safety of performance of the wall system have been performed.

Related Code Sections


1704.10.1 Structural Tests and Special Inspections, Special Inspection for Wall Panels, Curtain Walls and Veneers
The special inspector shall become familiar with and retain a copy of the construction documents, shop drawings, instructions for the sequence ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.10 Wall Panels, Curtain Walls and Veneers > 1704.10.1 Special Inspection for Wall Panels, Curtain Walls and Veneers
1704.10.2 Structural Tests and Special Inspections, Inspection Program
The special inspector shall field check the site conditions at the time the structure is prepared for component installation, and periodically during ...
NYC Building Code 2014 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.10 Wall Panels, Curtain Walls and Veneers > 1704.10.2 Inspection Program
1705.20.2 Special Inspections and Tests, Inspection Program
The special inspector shall field check the site conditions at the time the structure is prepared for component installation, and periodically during ...
NYC Building Code 2022 > 17 Special Inspections and Tests > 1705 Required Special Inspections and Tests > 1705.20 Wall Panels, Curtain Walls and Veneers > 1705.20.2 Inspection Program
1704.10 Structural Tests and Special Inspections, Wall Panels, Curtain Walls and Veneers
Special inspection is required for exterior architectural wall panels and the anchoring of veneers designed for installation on buildings above ...
NYC Building Code 2008 > 17 Structural Tests and Special Inspections > 1704 Special Inspections > 1704.10 Wall Panels, Curtain Walls and Veneers
Appendix A Selected Rules of the Department of Buildings [PDF] (page 143)
of Inspection Supervisor 1. General Building Construction Wall Panels, Curtain Walls, and Veneers BC 1704.10 • • RA or PE – Civil or Structural ...
NYC 1968 Code (Vol II) [PDF] > A Selected Rules of the Department of Buildings
Help Contact Us Privacy Terms
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING