Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

141-23 Special Height and Setback Regulations Along the Elevated Rail Structure Outside Subdistrict A

NYC Zoning Resolution > XIV - Special Purpose Districts > 1 Special Jerome Corridor District (J) > 141-20 Special Bulk Regulations > 141-23 Special Height and Setback Regulations Along the Elevated Rail Structure Outside Subdistrict A
JUMP TO FULL CODE CHAPTER
For zoning lots, or portions thereof, within 100 feet of street lines along the elevated rail structure on Jerome or River Avenues, and located outside Subdistrict A, the underlying height and setback provisions are modified by the provisions of this Section.
  1. Street wall location

    At least 70 percent of the aggregate width of street walls shall be located within eight feet of the street line and shall extend to at least a minimum base height of 15 feet, or the height of the building, whichever is lower. The remaining aggregate width of street walls may be recessed beyond eight feet of the street line, provided that any such recesses deeper than 10 feet along a wide street or 15 feet along a narrow street are located within an outer court.

    The underlying allowances for street wall articulation, set forth in paragraph (e) of Section 35-651 (Street wall location) shall be permitted to project or recess, where applicable, beyond the street wall locations established in this paragraph.

    Any open space between a street wall and a street line along the elevated rail structure on Jerome or River Avenues shall comply with the special open space provisions of paragraph (a) of Section 141-33.
  2. Base heights, maximum building heights and maximum number of stories

    The table in this Section sets forth, by zoning district, the minimum and maximum base height, the maximum height of a building or other structure, and the maximum number of stories for buildings, or portions thereof. For zoning lots in a Commercial District the applicable district shall be the Residence District within which such Commercial District is mapped, or the applicable residential equivalent set forth in the tables in Section 35-23 (Residential Bulk Regulations in Other C1 or C2 Districts or in C3, C4, C5 or C6 Districts).

    Separate maximum base heights are established in the table in this Section for street walls of buildings facing streets intersecting Jerome or River Avenues, and for street walls facing the elevated rail structure. The maximum base heights along intersecting streets shall also apply to street walls facing the elevated rail structure on Jerome or River Avenues within 75 feet of the corner.

    A setback is required for all portions of buildings or other structures that exceed the maximum base height specified for the district, and shall be provided at a height not lower than the minimum base height or higher than the permitted maximum base height. Such setback shall have a depth of at least 10 feet from any street wall fronting on a wide street, and a depth of at least 15 feet from any street wall fronting on a narrow street. The underlying provisions of paragraphs (c)(2) through (c)(4) of Section 23-662 (Maximum height of buildings and setback regulations) shall apply to such setbacks.


    BASE HEIGHTS, MAXIMUM BUILDING HEIGHTS AND MAXIMUM NUMBER OF STORIES
    District
    Maximum Base Height Along Elevated Rail Structure, beyond 75 feet of the corner (in feet)
    Maximum Base Height on Intersecting Streets, and within 75 feet of the corner (in feet)
    Maximum Height of Buildings or Other Structures (in feet)
    Maximum Number of Stories
    R7A
    30
    75
    115
    11
    R7D
    30
    95
    135
    13
    R8A
    30
    105
    165
    16
    R9A
    30
    125
    195
    19
  3. Required and permitted articulation

    For street walls fronting the elevated rail structure on Jerome or River Avenues with widths exceeding 100 feet, a minimum of 20 percent of the surface area of such street walls above the level of the second story, or a height of 30 feet, whichever is lower, shall either recess or project a minimum of three feet from the remaining surface of the street wall. Any such projections shall be considered a permitted obstruction into a required setback, and the depth of such projections along the elevated rail structure shall not exceed three feet.

    In addition, the underlying dormer provisions of paragraph (c) of Section 23-621 shall be modified for portions of buildings facing the elevated rail structure, so that above the maximum base height set forth in paragraph (b) of this Section, dormers shall be permitted only within 75 feet of a corner.

Related Code Sections


5.11.10 Special Application Elevators, Guarding of Equipment and Standard Railing
A standard railing shall be substantially constructed of metal and shall consist of a top rail ...
Safety Code for Elevators and Escalators 2013 of New York City > 5 Special Application Elevators > 5.11 Wind Turbine Tower Elevators > 5.11.10 Guarding of Equipment and Standard Railing
2.10.2 Electric Elevators, Standard Railing
A standard railing shall be substantially constructed of metal and shall consist of a top rail, intermediate rail or equivalent structural member ...
Safety Code for Elevators and Escalators 2013 of New York City > 2 Electric Elevators > 2.10 Guarding of Equipment and Standard Railing > 2.10.2 Standard Railing
*3114.12 Special Construction, Setback
than one-half the height of such turbine, including such tower, measured from the base of such tower or, if there is no such tower, the base ...
NYC Building Code 2014 > 31 Special Construction > *3114 Large Wind Turbines > *3114.12 Setback
*3114.12 Special Construction, Setback
than one-half the height of such turbine, including such tower, measured from the base of such tower or, if there is no such tower, the base ...
NYC Building Code 2022 > 31 Special Construction > *3114 Large Wind Turbines > *3114.12 Setback
5.7.17 Special Application Elevators, Car Guide Rails and Guide-Rail Fastenings
Guide rails shall extend from the bottom of the hoistway ...
Safety Code for Elevators and Escalators 2013 of New York City > 5 Special Application Elevators > 5.7 Special Purpose Personnel Elevators > 5.7.17 Car Guide Rails and Guide-Rail Fastenings
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING