109-131 Building Facades
The front building wall of any building shall extend along the full length of its front lot line not occupied by existing buildings to remain and shall rise without setback up to a height of six stories or 65 feet, or the height of the building, whichever is less. Above that height, the front building wall shall set back at least 10 feet. Front wall recesses are permitted provided that the aggregate length of such recesses, excluding window fenestration, at the level of any story does not exceed 25 percent of the length of the front wall where such recesses are permitted. In the event that a development occupies an entire block frontage, additional recesses are permitted provided that there are no front wall recesses within 10 feet of the intersection of two street lines. The exterior building materials of the front wall shall be predominantly of masonry.
109-132 Treatment of the Ground Level Wall
For buildings developed after February 3, 1977, and for buildings enlarged on the ground floor level after February 3, 1977, at least 25 percent of the total surface area of the entire front wall of a development or the enlarged portion, up to a height of 12 feet above curb level or to the ceiling of the ground story, whichever is higher, shall be transparent. Transparent areas may include storefronts subject to Section 109-50. Door or window openings within such surface areas shall be considered transparent. Such opening shall have a minimum width of two feet. In addition, any portion of such building wall 20 feet or more in length, which contains no transparent areas at ground floor level, shall be covered with vines or similar planting in permitted front wall recesses, or be treated so as to provide visual relief from large expanses of blank walls. Planting shall consist of shrubs, ivy or creepers and shall be planted in soil having a depth of not less than 2 feet, 6 inches, and a minimum width of 24 inches.

Related Code Sections

Section 310 General Regulations, Washroom and Toilet Room Requirements
front lip of the urinal measured from the finished back wall surface, whichever is greater. Exceptions: Urinal partitions shall not be required ...
Article 13 Special Occupancy Structures [PDF] (page 10)
Sub-Article 10. Normal Exits in Special Occupancy Structures (12.10.1). §C26-730.0 Normal Street Exits.a. Every structure intended to be used ...
Article 13 Special Occupancy Structures [PDF] (page 5)
floor extending from each side of the proscenium opening to the enclosure walls and from the stage side of the proscenium wall to the front edge ...
Section 306 General Regulations, Access and Service Space
inches deep and 30 inches wide (762 mm by 762 mm) shall be provided in front of the control side to service an appliance. Clearance shall also ...
Section 306 General Regulations, Access and Service Space
, serviced, repaired or replaced. A level working space at least 30 inches deep and 30 inches wide (762 mm by 762 mm) shall be provided in front ...