406.0 Special Fixtures and Specialties
Go To Full Code Chapter
406.1 Water and Waste Connections
Baptisteries, ornamental and lily ponds, aquaria, ornamental fountain basins, and similar fixtures and specialties requiring water, waste connections, or both shall be submitted for approval to the Authority Having Jurisdiction prior to installation.
406.2 Special Use Sinks
Restaurant kitchen and other special use sinks shall be permitted to be made of approved-type bonderized and galvanized sheet steel of not less than No. 16 U.S. gauge (0.0635 inches) (1.6 mm). Sheet-metal plumbing fixtures shall be adequately designed, constructed, and braced in an approved manner to accomplish their intended purpose.
406.3 Special Use Fixtures
Special use fixtures shall be made of one of the following:
- Soapstone
- Chemical stoneware
- Copper-based alloy
- Nickel-based alloy
- Corrosion-resistant steel
- Other materials suited for the intended use of the fixture
406.4 Zinc Alloy Components
Zinc alloy components shall comply with applicable nationally recognized standards and shall be used in accordance with their listing.
Upcodes Diagrams
Related Code Sections
406.0 Plumbing Fixtures and Fixture Fittings, Special Fixtures and Specialties
Baptisteries, ornamental and lily ponds, aquaria, ornamental fountain basins, and similar fixtures and specialties requiring water, waste connections ...
Section P2724 Plumbing Fixtures, Specialty Temperature Control Devices and Valves
-actuated, flow-reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall not be used ...
P2724.2 Plumbing Fixtures, Temperature-Actuated, Flow-Reduction Devices for Individual Fixtures
Temperature-actuated, flow-reduction devices, where installed for individual fixture fittings, shall conform to ASSE 1062. Such valves shall ...
422.3 Plumbing Fixtures and Fixture Fittings, Fixture Requirements for Special Occupancies
Additional fixtures shall be permitted to be required where unusual environmental conditions or referenced activities are encountered. In food ...
601.3.4 Water Supply and Distribution, Fixtures
Where vacuum breakers or backflow preventers are installed with fixtures listed in Chapter 17, identification of the discharge side shall ...