• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

117-63 Special Bulk Regulations in the Designated Districts

NYC Zoning Resolution > XI Special Purpose Districts > 7 - Special Long Island City Mixed Use District (LIC) > 117-60 Dutch Kills Subdistrict > 117-63 Special Bulk Regulations in the Designated Districts
JUMP TO FULL CODE CHAPTER
Maximum floor area ratio, lot coverage and street wall provisions in the designated districts are modified as set forth in Sections 117-631 through 117-633, inclusive.

117-631 Floor Area Ratio and Lot Coverage Modifications

(a)        In the Dutch Kills Subdistrict, the floor area of a building shall not include floor space used for accessory off-street parking spaces provided in any story located not more than 33 feet above curb level, in any building, except where such floor space used for accessory parking is contained within a public parking garage.
(b)        Maximum floor area ratio and lot coverage for residential uses
(1)        M1-2/R5B designated district

The maximum floor area ratio for residential use shall be 1.65.

The maximum lot coverage for the residential portion of a building shall be 60 percent on an interior lot or through lot and 80 percent on a corner lot.
(2)        M1-3/R7X designated district
(i)        Inclusionary Housing Program

Where the designated district is M1-3/R7X within the Dutch Kills Subdistrict, such district shall be an Inclusionary Housing designated area, pursuant to Section 12-10 (DEFINITIONS), for the purpose of making the Inclusionary Housing Program regulations of Section 23-90, inclusive, applicable as modified within the Special District.
(ii)        Maximum floor area ratio

Within such Inclusionary Housing designated area, the maximum floor area ratio for any zoning lot containing a residential use shall not exceed the base floor area ratio of 3.75, except that such base floor area ratio may be increased to the maximum floor area ratio of 5.0, as set forth in Section 23-154 (Inclusionary Housing), through the provision of affordable housing, pursuant to the provisions relating to Inclusionary Housing designated areas in Section 23-90.
(c)        Maximum floor area ratio for certain commercial and manufacturing uses

In M1-2 designated districts, the maximum floor area ratio shall be increased to 3.0 when paired with an R5B or R5D District and 4.0 when paired with an R6A District, provided that such additional floor area is limited to the following uses: photographic or motion picture production studios and radio or television studios listed in Use Group 10A; and uses listed in Use Groups 16A, 16D, 17A and 17B as set forth in Section 123-22 (Modification of Use Groups 16, 17 and 18), except for automobile, motorcycle, trailer or boat sales, motorcycle or motor scooter rental establishments, poultry or rabbit killing establishments, riding academies, stables for horses and trade schools for adults.

117-632 Street Wall Location

In the Dutch Kills Subdistrict, the street wall of any residential or mixed use building shall be located no closer to, nor further from, the street line than the street wall of an adjacent existing building. For all zoning lots, the street wall of a building need not be located further from the street line than 15 feet.

117-633 Maximum Street Wall Height

In M1-2/R5B designated districts, for residential buildings, the maximum height of a street wall above the base plane shall be 33 feet or three stories, whichever is less.

117-634 Maximum Building Height for Mixed Use Buildings in Designated R5 Districts

The provisions regarding the maximum height of mixed use buildings within 25 feet of a street line, as set forth in Section 123-661 (Mixed use buildings in Special Mixed Use
Districts with R3, R4 or R5 District designations), shall be modified in the Dutch Kills Subdistrict, where the designated Residence District is an R5 District, as follows:
(a)        in designated R5B Districts, no building or other structure shall exceed a height of 33 feet within 25 feet of a street line;
(b)        in designated R5D Districts, no building or other structure shall exceed a height of 45 feet within 25 feet of a street line.

Related Code Sections


D101.1 Fire Districts, Scope
The provisions of this appendix shall regulate the division of the city of New York into geographical territories known as fire districts and control ...
NYC Building Code 2014 > D Fire Districts > D101 General > D101.1 Scope
D101.1 Fire Districts, Scope
The provisions of this appendix shall regulate the division of the city of New York into geographical territories known as fire districts and control ...
NYC Building Code 2008 > D Fire Districts > D101 General > D101.1 Scope
D101.1 Fire Districts, Scope
The provisions of this appendix shall regulate the division of the city of New York into geographical territories known as fire districts and control ...
NYC Building Code 2022 > D Fire Districts > D101 General > D101.1 Scope
§27-288 Building Limitations, Scope
The provisions of this article establish building access requirements; shall regulate the division of the city of New York into fire districts ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 1 General > §27-288 Scope
Article 3 Building Limitations, Fire Districts
not included inside the fire districts shall be designated as outside fire districts ...
NYC 1968 Code (Vol I) > 4 Building Limitations > 3 Fire Districts
Help Contact Us Privacy Terms
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING