// CODE SNIPPET
609.3 Spacing
JUMP TO FULL CODE CHAPTER
The space between the wall and the grab bar shall be 11/2 inches (38 mm). The space between the grab bar and projecting objects below and at the ends shall be 11/2 inches (38 mm) minimum. The space between the grab bar and projecting objects above shall be 12 inches (305 mm) minimum.
EXCEPTION: The space between the grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 11/2 inches (38 mm) minimum.
![]() |
Related Code Sections
609.3 Plumbing Elements and Facilities, Spacing
The space between the wall and the grab bar shall be 1 1 / 2 inches (38 mm). The space between the grab bar and projecting objects below ...
1005.5 Recreation Facilities, Turning Space
At least one turning space complying with 304.3 shall be provided on fishing piers and platforms ...
2010 ADA Standards > 10 Recreation Facilities > 1005 Fishing Piers and Platforms > 1005.5 Turning Space
1008.3.1.3 Recreation Facilities, Transfer Space
A transfer space complying with 305.2 and 305.3 shall be provided adjacent to the transfer platform. The 48 inch (1220 mm) long minimum ...
2010 ADA Standards > 10 Recreation Facilities > 1008 Play Areas > 1008.3 Transfer Systems > 1008.3.1 Transfer Platforms > 1008.3.1.3 Transfer Space
1009.5.2 Recreation Facilities, Transfer Space
A transfer space of 60 inches (1525 mm) minimum by 60 inches (1525 mm) minimum with a slope not steeper than 1:48 shall be provided at the base ...
2010 ADA Standards > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.5 Transfer Systems > 1009.5.2 Transfer Space
1010.1 Recreation Facilities, Turning Space
A circular turning space 60 inches (1525 mm) diameter minimum with slopes not steeper than 1:48 shall be provided at shooting facilities with firing ...