2110.3.4 Solid Units
Related Code Sections
2104.1.2.3 Masonry, Solid Units
Unless otherwise required or indicated on the construction documents, solid units shall be placed in fully mortared bed and head joints. The ends ...
2109.6.2.1 Masonry, Solid Units
Where the facing and backing (adjacent wythes) of solid masonry construction are bonded by means of masonry headers, no less than 4 percent ...
2110.3.4 Masonry, Solid Units
The maximum area of solid glass-block wall panels in both exterior and interior walls shall not be more than 100 square feet (9.3 m2) ...
3.3.124 Definitions, Solid Masonry Unit
A masonry unit whose net cross-sectional area in every plane parallel to the bearing surface is 75 percent or more of its gross cross-sectional area ...
3.9.2.8 Definitions, Solid Unit Load of Unexpanded Plastic (Either Cartoned or Exposed)
A load that does not have voids (air) within the load and that burns only on the exterior of the load; water from sprinklers might reach most surfaces ...