• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

Section 3207 Solid-Piled and Shelf Storage

Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage
JUMP TO FULL CODE CHAPTER

3207.1 General

Shelf storage and storage in solid piles, solid piles on pallets and bin box storage in bin boxes not exceeding 5 feet (1524 mm) in any dimension, shall be in accordance with Section 3206 and this section.

3207.2 Fire Protection

Where automatic sprinklers are required by Table 3206.2, an approved automatic sprinkler system shall be installed throughout the building or to 1-hour fire barriers constructed in accordance with Section 707 of the International Building Code. Openings in such fire barriers shall be protected by opening protectives having a 1-hour fire protection rating. The design and installation of the automatic sprinkler system and other applicable fire protection shall be in accordance with the International Building Code and NFPA 13.

3207.2.1 Shelf Storage

Shelf storage greater than 12 feet (3658 mm) but less than 15 feet (4572 mm) in height shall be in accordance with the fire protection requirements set forth in NFPA 13. Shelf storage 15 feet (4572 mm) or more in height shall be protected in an approved manner with special fire protection, such as in-rack sprinklers.

3207.3 Pile Dimension and Height Limitations

Pile dimensions, the maximum permissible storage height and pile volume shall be in accordance with Table 3206.2.

3207.4 Arrays

Where an automatic sprinkler system design utilizes protection based on a closed array, array clearances shall be provided and maintained as specified by the standard used.

Related Code Sections


Section 3207 High-Piled Combustible Storage, Solid-Piled and Shelf Storage
Shelf storage and storage in solid piles, solid piles on pallets and bin box storage in bin boxes not exceeding 5 feet (1524 mm) in any dimension ...
Fire Code 2021 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage
Section 3207 High-Piled Combustible Storage, Solid-Piled and Shelf Storage
Shelf storage and storage in solid piles, solid piles on pallets and bin box storage in bin boxes not exceeding 5 feet (1524 mm) in any dimension ...
Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage
3207.3 High-Piled Combustible Storage, Pile Dimension and Height Limitations
Pile dimensions, the maximum permissible storage height and pile volume shall be in accordance with Table 3206.2 ...
Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage > 3207.3 Pile Dimension and Height Limitations
3207.4 High-Piled Combustible Storage, Arrays
Where an automatic sprinkler system design utilizes protection based on a closed array, array clearances shall be provided and maintained ...
Fire Code 2021 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage > 3207.4 Arrays
3207.4 High-Piled Combustible Storage, Arrays
Where an automatic sprinkler system design utilizes protection based on a closed array, array clearances shall be provided and maintained ...
Fire Code 2018 of Colorado > 32 High-Piled Combustible Storage > 3207 Solid-Piled and Shelf Storage > 3207.4 Arrays
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING