1024.3.1 Solid and Continuous
JUMP TO FULL CODE CHAPTER
For the purposes of this section, solid and continuous means without gaps or interruption, except as required for the control of expansion and contraction. A series of dashes, chevrons, dots, or other similar patterns is not solid and continuous. Luminous materials shall be considered solid and continuous if they occasionally contain the following safety green (ANSI Z 535.1) symbols or text:
- The word "EXIT";
- Egress symbol as per NFPA 170;
- Direction arrows as per NFPA 170; or
- Other text or symbols as approved by the commissioner.
Related Code Sections
1024.3.1 Means of Egress, Solid and Continuous
For the purposes of this section, solid and continuous means without gaps or interruption, except as required for the control of expansion ...
NYC Building Code 2014 > 10 Means of Egress > 1024 Luminous Egress Path Markings > 1024.3 Uniformity > 1024.3.1 Solid and Continuous
Reference Standard 6 Means of Egress [PDF] (page 14)
frame. This photoluminescent stripe shall not be zebra striped but must be solid and continuous as per ยงยง 2.2.9.3, 2.3.2, and 2.3.4. revision: July 1 ...
Reference Standard 6 Means of Egress [PDF] (page 4)
intermediate and final exit doors shall be marked with a solid and continuous 1" to 2" (25 mm to 51 mm) wide stripe of photoluminescent material. Gaps ...
Reference Standard 6 Means of Egress [PDF] (page 2)
step shall be marked with a solid and continuous stripe of photoluminescent material. The dimensions, distances and locations shall be consistent ...
306.2 General Regulations, Trenching and Bedding
Where trenches are excavated such that the bottom of the trench forms the bed for the pipe, solid and continuous load-bearing support shall ...
NYC Plumbing Code 2008 > 3 General Regulations > 306 Trenching, Excavation and Backfill > 306.2 Trenching and Bedding