Soldering bushings shall be of copper or copper alloy and shall be in accordance with Table 705.19.
TABLE 705.19
SOLDERING BUSHING SPECIFICATIONS
PIPE SIZES (inches) MINIMUM WEIGHT EACH
11/4 6 ounces
11/2 8 ounces
2 14 ounces
21/2 1 pound 6 ounces
3 2 pounds
4 3 pounds 8 ounces
For SI: 1 inch = 25.4 mm, 1 ounce = 28.35 g, 1 pound = 0.454 kg.