3.3.2 Soft Story
Go To Full Code Chapter
Visual observation or a Quick Check indicates that there are no significant stiffness discontinuities in any of the vertical elements in the lateral-force-resisting system; the lateral stiffness of a story is not less than 70 percent of that in the story above or less than 80 percent of the average stiffness of the three stories above.
For buildings designed and constructed in accordance with the 1989 or later editions of Part 2, Title 24, the evaluator may consider this condition as mitigated, and no calculations are necessary. The deficiency is in the stiffness of certain portions of the building. Where a soft story condition is indicated, the stiffness of the building shall be calculated story by story, in order to determine whether a story falls within the definition of a soft story. Where a soft story exists, the resisting elements shall be checked; include P-delta effects. For buildings more than 65 feet or five stories tall, a dynamic analysis shall be performed to compute the distribution of seismic forces.
Related Code Sections
3.3.2 Seismic Evaluation Procedures for Hospital Buildings, Soft Story
of the building. Where a soft story condition is indicated, the stiffness of the building shall be calculated story by story, in order to determine whether ...
3.3.2 Seismic Evaluation Procedures for Hospital Buildings, Soft Story
of the building. Where a soft story condition is indicated, the stiffness of the building shall be calculated story by story, in order to determine whether ...
3.3.2 Seismic Evaluation Procedures for Hospital Buildings, Soft Story
of the building. Where a soft story condition is indicated, the stiffness of the building shall be calculated story by story, in order to determine whether ...
A403.9.1 Earthquake Risk Reduction in Wood-Frame Residential Buildings With Soft, Weak or Open Front Walls, Gypsum or Cement Plaster Products
Gypsum or cement plaster products shall not be used to provide lateral resistance in a soft or weak story or in a story with an open-front wall line ...
303A.3.4.5 Provisions for All Compliance Methods, SPC-4D Using ASCE 41
does not have any of the following structural deficiencies as defined in CAC, Chapter 6, Article 3:
Load path (3.1)
Weak story (3.3.1)
Soft ...
California Existing Building Code 2019 > 3A Provisions for All Compliance Methods > 303A Structural Design Loads and Evaluation and Design Procedures > 303A.3 Additions, Alterations, Repairs and Seismic Retrofit to Existing Buildings or Structures > 303A.3.4 Performance Objectives of Performance-Based Methods > 303A.3.4.5 SPC-4D Using ASCE 41