1709.10.1 Product Approval
Manufactured soffit materials and systems shall be subject to statewide or local product approval as specified in Florida Administrative Code Rule 61G-20. The net free area of the manufactured soffit material or system shall be included in the product approval submittal documents.
1709.10.2 Labels
Individual manufactured soffit pieces shall be marked at not more than 4 feet (1.2 m) on center with a number or marking that ties the product back to the manufacturer.
1709.10.3
The following information shall be included on the manufactured soffit material packaging or on the individual manufactured soffit material or system pieces:
  1. Product approval holder and/or manufacturer name and city and state of manufacturing plant.
  2. Product model number or name.
  3. Method of approval and approval numbers as applicable. Methods of approval include, but are not limited to: Florida Building Commission FL #; MiamiDade NOA; TDI Product Evaluation; and ICC-ES.
  4. The test standard or standards specified in Chapter 14 used to demonstrate code compliance.
  5. The net free area shall be included on the packaging or label.
Upcodes Diagrams

Related Code Sections

1709.10 Special Inspections and Tests, Soffit
Manufactured soffit materials and systems shall be subject to statewide or local product approval as specified in Florida Administrative Code Rule ...
1709.10 Special Inspections and Tests, Soffit
Manufactured soffit materials and systems shall be subject to statewide or local product approval as specified in Florida Administrative Code Rule ...
1710.9 Special Inspections and Tests, Soffit
Manufactured soffit materials and systems shall be subject to statewide or local product approval as specified in Florida Administrative Code (FAC ...
Section R704 Wall Covering, Soffits
Soffits and their attachments shall be capable of resisting wind loads specified in Tables R301.2(2) and R301.2(3) for walls using an effective wind ...