Every required exit stairway serving floors more than 75 feet (22 860 mm) above the lowest level of fire department vehicle access shall comply with Sections 909.20 and 1022.9.
Upcodes Diagrams

Related Code Sections

1023.11 Means of Egress, Smokeproof Enclosures
Where required by Section 403.5.4 or 405.7.2, interior exit stairways and ramps shall be smokeproof enclosures in accordance with Section 909.20 ...
1023.12 Means of Egress, Smokeproof Enclosures
Where required by Section 403.5.4, 405.7.2 or 412.2.2.1, interior exit stairways and ramps shall be smokeproof enclosures in accordance with Section ...
1023.11 Means of Egress, Smokeproof Enclosures
Where required by Section 403.5.4 or 405.7.2 of the International Building Code, interior exit stairways and ramps shall be smokeproof enclosures ...
1023.12 Means of Egress, Smokeproof Enclosures
smokeproof enclosure shall terminate at an exit discharge or a public way. The smokeproof enclosure shall be permitted to be extended by an exit passageway ...