// CODE SNIPPET
1022.9 Smokeproof Enclosures and Pressurized Stairways
JUMP TO FULL CODE CHAPTER
In buildings required to comply with Section 403 or 405, each of the exit enclosures serving a story with a floor surface located more than 75 feet (22 860 mm) above the lowest level of Fire Department vehicle access or more than 30 feet (9144 mm) below the finished floor of a level of exit discharge serving such stories shall be a smokeproof enclosure or pressurized stairway in accordance with Section 909.20.
A smokeproof enclosure or pressurized stairway shall terminate at an exit discharge or a public way. The smokeproof enclosure or pressurized stairway shall be permitted to be extended by an exit passageway in accordance with Section 1022.2. The exit passageway shall be without openings other than the fire door assembly required by Section 1022.2 and those necessary for egress from the exit passageway. The exit passageway shall be separated from the remainder of the building by 2-hour fire barriers constructed in accordance with Section 707 or horizontal assemblies constructed in accordance with Section 712, or both.
Exceptions:
Exceptions:
- Openings in the exit passageway serving a smokeproof enclosure are permitted where the exit passageway is protected and pressurized in the same manner as the smokeproof enclosure, and openings are protected as required for access from other floors.
- Openings in the exit passageway serving a pressurized stairway are permitted where the exit passageway is protected and pressurized in the same manner as the pressurized stairway.
- The fire barrier separating the smokeproof enclosure or pressurized stairway from the exit passageway is not required, provided the exit passageway is protected and pressurized in the same manner as the smokeproof enclosure or pressurized stairway.
- A smokeproof enclosure or pressurized stairway shall be permitted to egress through areas on the level of discharge or vestibules as permitted by Section 1027.
Access to the stairway within a smokeproof enclosure shall be by way of a vestibule or an open exterior balcony.
Exception: Access is not required by way of a vestibule or exterior balcony for stairways using the pressurization alternative complying with Section 909.20.5.
Exception: Access is not required by way of a vestibule or exterior balcony for stairways using the pressurization alternative complying with Section 909.20.5.
Related Code Sections
1022.9 Means of Egress, Smokeproof Enclosures and Pressurized Stairways
discharge serving such stories shall be a smokeproof enclosure or pressurized stairway in accordance with Section 909.20 ...
NYC Building Code 2014 > 10 Means of Egress > 1022 Exit Enclosures > 1022.9 Smokeproof Enclosures and Pressurized Stairways
1019.1.8 Means of Egress, Smokeproof Enclosures
discharge serving such floor levels shall be a smokeproof enclosure or pressurized stairway in accordance with Section 909.20 ...
NYC Building Code 2008 > 10 Means of Egress > 1019 Vertical Exit Enclosures > 1019.1 Enclosures Required > 1019.1.8 Smokeproof Enclosures
Section 1019 Means of Egress, Vertical Exit Enclosures
the level of exit discharge serving such floor levels shall be a smokeproof enclosure or pressurized stairway in accordance with Section 909.20 ...
403.4.7.2 Special Detailed Requirements Based on Use and Occupancy, Standby Power Loads in Occupancies Other Than Group R-2
center required by Section 403.4.5; Ventilation and automatic fire detection equipment for smokeproof enclosures; Elevators, in accordance ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 403 High-Rise Buildings > 403.4 Emergency Systems > 403.4.7 Standby Power > 403.4.7.2 Standby Power Loads in Occupancies Other Than Group R-2
405.8.1 Special Detailed Requirements Based on Use and Occupancy, Standby Power Loads
for smokeproof enclosures; Fire pumps; Elevators in accordance with Section 3003; and Stair pressurization systems when provided ...
NYC Building Code 2014 > 4 Special Detailed Requirements Based on Use and Occupancy > 405 Underground Buildings and Spaces > 405.8 Standby Power > 405.8.1 Standby Power Loads