• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1301.6.20 Smoke Compartmentation

Existing Building Code 2018 of Illinois > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.20 Smoke Compartmentation
JUMP TO FULL CODE CHAPTER
Evaluate the smoke compartments for compliance with Section 407.5 of the International Building Code. Under the categories and occupancies in Table 1301.6.20, determine the appropriate smoke compartmentation value (SCV) and enter that value into Table 1301.7 under Safety Parameter 1301.6.20, Smoke Compartmentation, for fire safety, means of egress and general safety. Facilities in Group I-2 occupancies meeting Category b or c shall be considered to fail the evaluation.
TABLE 1301.6.20
SMOKE COMPARTMENTATION VALUES
OCCUPANCYCATEGORIESa
abc
A, B, E, F, M, R and S000
I-20NPNP
For SI: 1 square foot = 0.093 m2.
NP = Not Permitted.
  1. For areas between categories, the smoke compartmentation value shall be obtained by linear interpolation.

1301.6.20.1 Categories

Categories for smoke compartment size are:
  1. Category a—Smoke compartment size is equal to or less than 22,500 square feet (2092 m2).
  2. Category b—Smoke compartment size is greater than 22,500 square feet (2092 m2).
  3. Category c—Smoke compartments are not provided.

Related Code Sections


1301.6.20 Performance Compliance Methods, Smoke Compartmentation
1301.6.20, determine the appropriate smoke compartmentation value (SCV) and enter that value into Table 1301.7 under Safety Parameter 1301.6.20 ...
Existing Building Code 2018 of Illinois > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.20 Smoke Compartmentation
1301.6.20 Performance Compliance Methods, Smoke Compartmentation
1301.6.20, determine the appropriate smoke compartmentation value (SCV) and enter that value into Table 1301.7 under Safety Parameter 1301.6.20 ...
Existing Building Code 2021 of Illinois > 13 Performance Compliance Methods > 1301 General > 1301.6 Evaluation Process > 1301.6.20 Smoke Compartmentation
422.3.1 Special Detailed Requirements Based on Occupancy and Use, Means of Egress
Where ambulatory care facilities require smoke compartmentation in accordance with Section 422.3, the fire safety evacuation plans provided ...
Building Code 2021 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 422 Ambulatory Care Faciilities > 422.3 Smoke Compartments > 422.3.1 Means of Egress
422.3.1 Special Detailed Requirements Based on Occupancy and Use, Means of Egress
Where ambulatory care facilities require smoke compartmentation in accordance with Section 422.3, the fire safety evacuation plans provided ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 422 Ambulatory Care Faciilities > 422.3 Smoke Compartments > 422.3.1 Means of Egress
422.3 Special Detailed Requirements Based on Occupancy and Use, Smoke Compartments
be provided with a smoke barrier to subdivide the story into not fewer than two smoke compartments . The area of any one such smoke compartment ...
Building Code 2018 of Illinois > 4 Special Detailed Requirements Based on Occupancy and Use > 422 Ambulatory Care Faciilities > 422.3 Smoke Compartments
Help Contact Us Privacy Terms
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING