// CODE SNIPPET

R1001.8 Smoke Chamber

Residential Code 2015 of Utah > 10 Chimneys and Fireplaces > R1001 MASONRY FIREPLACES > R1001.8 Smoke Chamber
JUMP TO FULL CODE CHAPTER
Smoke chamber walls shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete. The total minimum thickness of front, back and side walls shall be 8 inches (203 mm) of solid masonry. The inside surface shall be parged smooth with refractory mortar conforming to ASTM C 199. Where a lining of firebrick not less than 2 inches (51 mm) thick, or a lining of vitrified clay not less than 5/8 inch (16 mm) thick, is provided, the total minimum thickness of front, back and side walls shall be 6 inches (152 mm) of solid masonry, including the lining. Firebrick shall conform to ASTM C 1261 and shall be laid with medium duty refractory mortar conforming to ASTM C 199. Vitrified clay linings shall conform to ASTM C 315.

R1001.8.1 Smoke Chamber Dimensions

The inside height of the smoke chamber from the fireplace throat to the beginning of the flue shall not be greater than the inside width of the fireplace opening. The inside surface of the smoke chamber shall not be inclined more than 45 degrees (0.79 rad) from vertical where prefabricated smoke chamber linings are used or where the smoke chamber walls are rolled or sloped rather than corbeled. Where the inside surface of the smoke chamber is formed by corbeled masonry, the walls shall not be corbeled more than 30 degrees (0.52 rad) from vertical.
Share URL

Copy and paste the link below into emails, chats or browsers.

Copy

You can also copy or bookmark the link from your browser's address bar.

Related Code Sections


R1001.8 Chimneys and Fireplaces, Smoke Chamber
Smoke chamber walls shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete. The total minimum thickness ...
Residential Code 2015 of Utah > 10 Chimneys and Fireplaces > R1001 MASONRY FIREPLACES > R1001.8 Smoke Chamber
2111.9 Masonry, Smoke Chamber Walls
Smoke chamber walls shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete. The total minimum thickness ...
Building Code 2015 of Utah > 21 Masonry > 2111 Masonry Fireplaces > 2111.9 Smoke Chamber Walls
2111.9 Masonry, Smoke chamber walls
Smoke chamber walls shall be constructed of solid masonry units, hollow masonry units grouted solid, stone or concrete. The total minimum thickness ...
Building Code 2018 of Utah > 21 Masonry > 2111 Masonry Fireplaces > 2111.9 Smoke chamber walls
R1001.6 Chimneys and Fireplaces, Firebox Dimensions
the firebox, including the throat, damper and smoke chamber, shall not be less than the cross-sectional area of the flue. Exception: Rumford ...
Residential Code 2015 of Utah > 10 Chimneys and Fireplaces > R1001 MASONRY FIREPLACES > R1001.6 Firebox Dimensions
2113.12 Masonry, Clay Flue Lining (Installation)
or, in the case of fireplaces, from the top of the smoke chamber to a point above the enclosing walls. The lining shall be carried up vertically ...
Building Code 2015 of Utah > 21 Masonry > 2113 Masonry Chimneys > 2113.12 Clay Flue Lining (Installation)
About UpCodes

UpCodes provides an intuitive resource to navigate building regulations.

Codes are organized by jurisdiction to help you understand which regulations apply to your project.


Find Your Codes
COMPANY INFO About Free Law Contact Careers Terms Privacy Press Kit
CATEGORY General New York City New York State California Codes Building Codes Online
PREMIUM Features Pricing Sign Up Log In
CODES IBC 2015 IRC 2015 IPC 2015 California Building Code 2016 Popular Sections

FOLLOW US