1104.4.4.1 Small Tiered Areas Utilizing the Floor Area at the Base of the Tier
Go To Full Code Chapter
Where a tiered area has no more than five tiers, the tier assembly has an occupant load of not more than 300, and the floor level at the base of the tier is utilized for the same use as the tiers, an accessible route shall be provided to the floor level at the base of the tier.