5606.5.2.3 Small Arms Primers
Go To Full Code Chapter
Commercial stocks of small arms primers shall be stored as follows:
- Quantities not to exceed 750,000 small arms primers stored in a building shall be arranged such that not more than 100,000 small arms primers are stored in any one pile and piles are not less than 15 feet (4572 mm) apart.
- Quantities exceeding 750,000 small arms primers stored in a building shall comply with all of the following:
- The warehouse or storage building is not open to unauthorized personnel.
- Small arms primers shall be stored in cabinets. Not more than 200,000 small arms primers shall be stored in any one cabinet.
- Shelves in cabinets shall have vertical separation of not less than 2 feet (610 mm).
- Cabinets shall be located against walls of the warehouse or storage room with not less than 40 feet (12 192 mm) between cabinets. The minimum required separation between cabinets shall be allowed to be reduced to 20 feet (6096 mm) provided that barricades twice the height of the cabinets are attached to the wall, midway between each cabinet. The barricades shall be firmly attached to the wall and shall be constructed of steel not less than 1/4 inch thick (6.4 mm), 2-inch (51 mm) nominal thickness wood, brick or concrete block.
- Small arms primers shall be separated from materials classified as combustible liquids, flammable liquids, flammable solids or oxidizing materials by a distance of 25 feet (7620 mm) or by a fire partition having a fire-resistance rating of 1 hour.
- The building shall be protected throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1.
- Small arms primers not stored in accordance with Item 1 or 2 of this section shall be stored in a magazine meeting the requirements of Section 5604 and NFPA 495.
Upcodes Diagrams
Related Code Sections
5606.4.3 Explosives and Fireworks, Small Arms Primers
Not more than 10,000 small arms primers shall be stored in occupancies limited to Group R-3 ...
5606.4.3 Explosives and Fireworks, Small Arms Primers
Not more than 10,000 small arms primers shall be stored in occupancies limited to Group R-3 ...
5606.1 Explosives and Fireworks, General
Indoor storage and display of black powder, smokeless propellants, small arms primers and small arms ammunition shall comply with this section ...
Section 5606 Explosives and Fireworks, Small Arms Ammunition and Small Arms Ammunition Components
Indoor storage and display of black powder, smokeless propellants, small arms primers and small arms ammunition shall comply with this section ...
5604.1 Explosives and Fireworks, General
Storage of explosives and explosive materials, small arms ammunition, small arms primers, propellant-actuated cartridges and smokeless propellants ...