1216.3 Sloping for One-Pipe System
Related Code Sections
1216.3 Hydronics, Sloping for One-Pipe System
One-pipe steam system piping and heat-distribution units shall be sloped down at not less than 1/8 inch per foot (10.4 mm/m) towards the steam boiler ...
E 301.2 Manufactured/Mobile Home Parks and Recreational Vehicle Parks, Underground Drainage System Location, Size, and Slope
A park drainage system that exceeds the fixture unit loading of Table E 301.2(1) or in which the grade and slope of drainage pipe do not meet ...
P3111.2 Vents, Installation
). The slope of horizontal combination waste and vent piping shall be not greater than 1/2 unit vertical in 12 units ...
P3111.2.1 Vents, Slope
The horizontal combination waste and vent pipe shall have a slope of not greater than 1/2 unit vertical in 12 units horizontal (4-percent slope). The ...
Section P3111 Vents, Combination Waste and Vent System
of horizontal combination waste and vent piping shall be not greater than 1/2 unit vertical in 12 units horizontal (4-percent slope) and shall be not less than ...