405.2 Slope
JUMP TO FULL CODE CHAPTER
Ramp runs shall have a running slope not steeper than 1:12.
EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 complying with Table 405.2 where such slopes are necessary due to space limitations.
Slope 1 | Maximum Rise |
---|---|
1. A slope steeper than 1:8 is prohibited. | |
Steeper than 1:10 but not steeper than 1:8 | 3 inches (75 mm) |
Steeper than 1:12 but not steeper than 1:10 | 6 inches (150 mm) |
Advisory 405.2 Slope. To accommodate the widest range of users, provide ramps with the least possible running slope and, wherever possible, accompany ramps with stairs for use by those individuals for whom distance presents a greater barrier than steps, e.g., people with heart disease or limited stamina.
Related Code Sections
1002.4.2 Recreation Facilities, Slope
The floor or ground surface of wheelchair spaces shall have a slope not steeper than 1:48 when in the load and unload position ...
2010 ADA Standards > 10 Recreation Facilities > 1002 Amusement Rides > 1002.4 Wheelchair Spaces in Amusement Rides > 1002.4.2 Slope
403.3 Accessible Routes, Slope
The running slope of walking surfaces shall not be steeper than 1:20. The cross slope of walking surfaces shall not be steeper than 1:48 ...
405.2 Accessible Routes, Slope
Ramp runs shall have a running slope not steeper than 1:12.
EXCEPTION : In existing sites, buildings, and facilities, ramps shall be permitted ...
810.2.4 Special Rooms, Spaces, and Elements, Slope
Parallel to the roadway, the slope of the bus stop boarding and alighting area shall be the same as the roadway, to the maximum extent practicable ...
2010 ADA Standards > 8 Special Rooms, Spaces, and Elements > 810 Transportation Facilities > 810.2 Bus Boarding and Alighting Areas > 810.2.4 Slope
1009.3 Recreation Facilities, Sloped Entries
Sloped entries shall comply with 1009.3. Advisory 1009.3 Sloped Entries. Personal wheelchairs and mobility devices may not be appropriate ...
2010 ADA Standards > 10 Recreation Facilities > 1009 Swimming Pools, Wading Pools, and Spas > 1009.3 Sloped Entries