1910.217(b)(9) Slide Counterbalance Systems
Go To Full Code Chapter
1910.217(b)(9)(i)
Spring counterbalance systems when used shall incorporate means to retain system parts in event of breakage.
1910.217(b)(9)(iii)
Air counterbalance cylinders shall incorporate means to retain the piston and rod in case of breakage or loosening.
1910.217(b)(9)(iv)
Air counterbalance cylinders shall have adequate capability to hold the slide and its attachments at any point in stroke, without brake applied.
1910.217(b)(9)(v)
Air counterbalance cylinders shall incorporate means to prevent failure of capability (sudden loss of pressure) in event of air supply failure.
1910.217(b)(9)(ii)
Spring counterbalances when used shall have the capability to hold the slide and its attachments at midstroke, without brake applied.
Upcodes Diagrams
Related Code Sections
1910.217(b)(9) Machinery and Machine Guarding, Slide Counterbalance Systems
Spring counterbalance systems when used shall incorporate means to retain system parts in event of breakage ...
1910.217(h)(3)(ii)(A) Machinery and Machine Guarding,
Where presses that have slide counterbalance systems are used in the PSDI mode, the counterbalance system shall also meet the requirements ...
1910.217(h)(10)(ii)(E) Machinery and Machine Guarding,
, when a press is equipped with a slide counterbalance system ...
1910.217(h)(3)(ii) Machinery and Machine Guarding, Air Counterbalance Systems
Where presses that have slide counterbalance systems are used in the PSDI mode, the counterbalance system shall also meet the requirements ...
1910.217(h)(3) Machinery and Machine Guarding, Pneumatic Systems
Where presses that have slide counterbalance systems are used in the PSDI ...