// CODE SNIPPET
1910.262(h) Slashers
Go To Full Code Chapter
—
1910.262(h)(1) Cylinder Dryers
—
1910.262(h)(1)(i) Reducing Valves, Safety Valves, and Pressure Gages
Reducing valves, safety valves, and pressure gages shall conform to the ASME Pressure Vessel Code, Section VIII, Unfired Pressure Vessels, 1968, which is incorporated by reference as specified in §1910.6.
1910.262(h)(1)(iii) Lever Control
When slashers are operated by control levers, these levers shall be connected to a horizontal bar or treadle located not more than 69 inches above the floor to control the operation from any point.
1910.262(h)(1)(iv) Pushbutton Control
Slashers operated by pushbutton control shall have stop and start buttons located at each end of the machine, and additional buttons located on both sides of the machine, at the size box and the delivery end. If calender rolls are used, additional buttons shall be provided at both sides of the machine at points near the nips, except when slashers are equipped with an enclosed dryer.
1910.262(h)(1)(v) Nip Guards
All nip guards shall comply with the requirements of paragraph (h)(2)(iv) of this section.
1910.262(h)(1)(vi) Cylinder Enclosure
1910.262(h)(1)(vii) Expansion Chambers
Slasher kettles and cookers shall be provided with expansion chambers in the covers, or drains, to prevent surging over. Steam-control valves shall be so located that they can be operated without exposing the worker to moving parts, hot surfaces, or steam.
1910.262(h)(1)(ii) Vacuum Relief Valves
Vacuum relief valves shall conform to the ASME Code for Pressure Vessels, Section VIII, Unfired Pressure Vessels, 1968.
1910.262(h)(2) Enclosed Hot Air Dryer
—
1910.262(h)(2)(i) Lever Control
When slashers are operated by control levers, these levers shall be connected to a horizontal bar or treadle located not more than 69 inches above the floor to control the operation from any point.
1910.262(h)(2)(iii) Dryer Enclosure
The dryer enclosure shall be provided with an exhaust system which will effectively prevent wet air and steam from escaping into the workroom.
1910.262(h)(2)(iv) Nip Guards
All nip guards shall comply with Table R-1.
The measurements in Table R-1 are all in inches.
Table R-1—Guard Openings
[Openings in the guard or between the guard and working surface shall not be greater than the following]
[Openings in the guard or between the guard and working surface shall not be greater than the following]
Distance of opening from nip point | Maximum width of opening |
0 to 11/2 | 1/4 |
11/2 to 21/2 | 3/8 |
21/2 to 31/2 | 1/2 |
31/2 to 51/2 | 5/8 |
51/2 to 61/2 | 3/4 |
61/2 to 71/2 | 7/8 |
71/2 to 81/2 | 11/4 |
The measurements in Table R-1 are all in inches.
1910.262(h)(2)(v) Expansion Chambers
Slasher kettles and cookers shall be provided with expansion chambers in the covers, or drains, to prevent surging over. Steam control valves shall be so located that they can be operated without exposing the worker to moving parts, hot surfaces, or steam.
1910.262(h)(2)(ii) Push-Button Control
Slashers operated by push-button control shall have one start button at each end of the machine and stop buttons shall be located on both sides of the machines at intervals spaced not more than 6 feet on centers. Inching buttons should be installed.
Upcodes Diagrams
Related Code Sections
1910.262(b)(34) Special Industries, Slasher
A slasher is a machine used for applying a size mixture to warp yarns. Essentially, it consists of a stand for holding section beams, a size box, one ...
1910.261(e)(2) Special Industries, Slasher Tables
Saws shall be stopped and power switches shall be locked out and tagged whenever it is necessary for any person to be on the slasher table ...
1910.262(h)(1)(ii) Special Industries, Vacuum Relief Valves
Vacuum relief valves shall conform to the ASME Code for Pressure Vessels, Section VIII, Unfired Pressure Vessels, 1968 ...
1910.262(h)(1)(iii) Special Industries, Lever Control
When slashers are operated by control levers, these levers shall be connected to a horizontal bar or treadle located not more than 69 inches above ...
1910.262(h)(1)(iv) Special Industries, Pushbutton Control
Slashers operated by pushbutton control shall have stop and start buttons located at each end of the machine, and additional buttons located on both ...