• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects
    Architects
    General Contractors
    General Contractors
    Building Official & Plans Examiners
    Building Official & Plans Examiners
    Inspectors
    Inspectors
    Owners
    Owners
    Subcontractors
    Subcontractors
    Code Consultants
    Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

1217.5.1 Slab Penetration Tube and Joint Protection

Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1217.0 Radiant Heating and Cooling > 1217.5 Poured Floor Structural Concrete Slab Systems (Thermal Mass) > 1217.5.1 Slab Penetration Tube and Joint Protection
JUMP TO FULL CODE CHAPTER
Where embedded in or installed under a concrete slab, tubing shall be protected from damage at penetrations of the slab with protective sleeving approved by the tubing manufacturer. The space between the tubing and sleeve shall be sealed with an approved sealant compatible with the tubing. The tubing at the location of an expansion joint in a concrete slab shall be encased in protective pipe sleeving that covers the tubing not less than 12 inches (305 mm) on either side of the expansion joint or the tubing shall be installed below the slab.

Related Code Sections


1217.5.1 Hydronics, Slab Penetration Tube and Joint Protection
Where embedded in or installed under a concrete slab, tubing shall be protected from damage at penetrations of the slab with protective sleeving ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1217.0 Radiant Heating and Cooling > 1217.5 Poured Floor Structural Concrete Slab Systems (Thermal Mass) > 1217.5.1 Slab Penetration Tube and Joint Protection
1220.2.3 Hydronics, Slab Penetration Tube and Joint Protection
Where embedded in or installed under a concrete slab, tubing shall be protected from damage at penetrations of the slab with protective sleeving ...
Uniform Mechanical Code 2018 of Nevada > 12 Hydronics > 1220.0 Auxiliary Systems > 1220.2 Snow and Ice Melt Controls > 1220.2.3 Slab Penetration Tube and Joint Protection
609.3 Water Supply and Distribution, Under Concrete Slab
to be wrapped. Copper or copper alloy tubing shall be installed without joints where possible. Where joints are permitted, they shall be brazed, and fittings ...
Uniform Plumbing Code 2018 of Nevada > 6 Water Supply and Distribution > 609.0 Installation, Testing, Unions, and Location > 609.3 Under Concrete Slab
707.8 Fire and Smoke Protection Features, Joints
Joints made in or between fire barriers , and joints made at the intersection of fire barriers with underside of a fire-resistance-rated floor ...
Building Code 2018 of Nevada > 7 Fire and Smoke Protection Features > 707 Fire Barriers > 707.8 Joints
707.8 Fire and Smoke Protection Features, Joints
Joints made in or between fire barriers , and joints made at the intersection of fire barriers with underside of a fire-resistance rated floor ...
Building Code 2012 of Nevada > 7 Fire and Smoke Protection Features > 707 Fire Barriers > 707.8 Joints
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code Compare
Code Compare
Highlight differences between any two building codes.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL PRICING