Section 602 Sizing Soil Absorption Systems
JUMP TO FULL CODE CHAPTER
Effluent from septic tanks and other approved treatment tanks shall be disposed of by soil absorption or an approved manner. Sizing shall be in accordance with this chapter for systems with a daily effluent application of 5,000 gallons (18 925 L) or less. Two systems of equal size shall be required for systems receiving effluents exceeding 5,000 gallons (18 925 L) per day. Each system shall have a minimum capacity of 75 percent of the area required for a single system. An approved means of alternating waste application shall be provided. A dual system shall be considered as one system.
A pressure distribution system shall be permitted in place of a conventional or dosing conventional soil absorption system where a site is suitable for a conventional private sewage disposal system. A pressure distribution system shall be approved as an alternative private sewage disposal system where the site is unsuitable for conventional treatment (for sizing and design criteria, see Chapter 7).
Related Code Sections
Section 602 Soil Absorption Systems, Sizing Soil Absorption Systems
Effluent from septic tanks and other approved treatment tanks shall be disposed of by soil absorption or an approved manner. Sizing shall ...
Private Sewage Disposal Code 2018 of South Holland > 6 Soil Absorption Systems > 602 Sizing Soil Absorption Systems
Section 602 Soil Absorption Systems, Sizing Soil Absorption Systems
Effluent from septic tanks and other approved treatment tanks shall be disposed of by soil absorption or an approved manner. Sizing shall ...
Private Sewage Disposal Code 2012 of South Holland > 6 Soil Absorption Systems > 602 Sizing Soil Absorption Systems
602.3 Soil Absorption Systems, Method of Discharge
Flow from the septic or treatment tank to the soil absorption system shall be by gravity or dosing for facilities with a daily effluent application ...
Private Sewage Disposal Code 2012 of South Holland > 6 Soil Absorption Systems > 602 Sizing Soil Absorption Systems > 602.3 Method of Discharge
Section 601 Soil Absorption Systems, General
The provisions of this chapter shall govern the sizing and installation of soil absorption systems ...
Section 601 Soil Absorption Systems, General
The provisions of this chapter shall govern the sizing and installation of soil absorption systems ...