In the districts indicated, all accessory off-street parking spaces shall comply with the size and location provisions of this Section.
36-521 Size of Spaces
C1 C2 C3 C4 C5 C6 C7 C8
In all districts, as indicated, for all accessory off-street parking spaces, open or enclosed, each 300 square feet of unobstructed standing or maneuvering area shall be considered one parking space. However, an area of less than 300 square feet, but in no event less than 200 square feet, may be considered as one space, where the layout and design of the parking area are adequate to permit convenient access and maneuvering in accordance with regulations promulgated by the Commissioner of Buildings, or where the developer or applicant for a building permit or certificate of occupancy certifies that such spaces will be fully attended.
Driveways used to access required parking spaces must be unobstructed for a width of at least eight feet and a height of eight feet above grade and, if connecting to a street, such driveway may only be accessed by a curb cut.
In any case where a reduction of the required area per parking space is permitted on the basis of the developer's certification that such spaces will be fully attended, it shall be set forth in the certificate of occupancy that paid attendants employed by the owners or operators of such spaces shall be available to handle the parking and moving of automobiles at all times when such spaces are in use.
In no event shall the dimensions of any parking stall be less than 18 feet long and 8 feet, 6 inches wide.
In the Borough of Staten Island and in lower density growth management areas in Community District 10 in the Borough of the Bronx, for commercial or community facility uses, each required parking space not within a building shall be within a parking stall accessed from a travel aisle, where each such stall and aisle complies with the maneuverability standards of paragraph (b) of Section 36-58 (Parking Lot Maneuverability and Curb Cut Regulations). The use of an attendant shall be permitted only where necessary to accommodate additional, non-required parking spaces within the travel aisles. For such parking areas with 18 or more spaces, or greater than 6,000 square feet in area, the provisions of Section 37-90 (PARKING LOTS) shall also apply.
36-522 Location of Parking Spaces in Certain Districts
C1-6A C1-7A C1-8A C1-8X C1-9A C2-6A C2-7A C2-7X C2-8A C4-2A C4-3A C4-4A C4-4D C4-4L C4-5A C4-5D C4-5X C4-6A C4-7A C5-1A C5-2A C6-2A C6-3A C6-3D C6-4A C6-4X
In the districts indicated, and in C1 and C2 Districts mapped within R5D, R6A, R6B, R7A, R7B, R7D, R7X, R8A, R8B, R8X, R9A, R9D, R9X, R10A and R10X Districts, and for Quality Housing buildings in C1, C2, C4, C5 and C6 Districts without a letter suffix, all accessory off-street parking spaces shall comply with the provisions of this Section.
  1. Buildings other than mixed buildings

    For any block front that is entirely within a Commercial District, accessory off-street parking spaces shall be located only within a building or in any open area on the zoning lot that is not between the street line and the street wall of the building or its prolongation. Where a zoning lot is bounded by more than one such street line, this provision shall apply along only one street line.
  2. Mixed buildings

    For mixed buildings, all accessory off-street parking spaces shall be located only within a building or in any open area on the zoning lot that is not between the street line and the street wall of the building or its prolongation.
36-523 Identification of Car Sharing Vehicles
C1 C2 C3 C4 C5 C6 C7 C8
Within an off-street parking facility that contains car sharing vehicles, an information plaque shall be placed within 20 feet of either the entrance to the parking facility or the attendant's station, at a location accessible to and visible to users of such facility. The plaque shall be fully opaque, non-reflective and constructed of permanent, highly durable materials and shall contain the following statements in lettering no less than one inch high:
  1. (a)        "Total parking spaces in facility:" which shall specify the total number of parking spaces permitted within such parking facility;
  2. "Maximum number of car sharing vehicles:" which shall specify the total number of car sharing vehicles permitted within such parking facility; and
  3. where such parking facility contains accessory residential parking spaces, "Accessory residential parking spaces shall be made available to residents of this building within 30 days after a written request is made to the landlord".
Upcodes Diagrams

Related Code Sections

904.4.1 Fire Protection Systems, Inspection
, location and spacing of automatic- and manual-initiating devices. Size, placement and position of nozzles or discharge orifices. Location ...
904.4.1 Fire Protection Systems, Inspection
Type, location and spacing of automatic- and manual initiating devices. Size, placement and position of nozzles or discharge orifices ...
904.4.1 Fire Protection Systems, Inspection
hazard.   2. Type, location and spacing of automatic- and manual-initiating devices.   3. Size, placement and position ...