   a.   Every water closet compartment shall be at least two feet, four inches in clear width.
   b.   The walls enclosing every water closet compartment shall extend from floor to ceiling except in general toilet or bath rooms.
   c.   The walls of every water closet compartment and general toilet or bath room shall be plastered, tiled or covered with similar materials approved by the department.
   d.   The floor of every water closet compartment, bath room or general toilet room shall be waterproofed with material approved by the department. Such waterproofing shall extend at least six inches above the floor, except at the doors.
   e.   Drip trays are prohibited.
   f.   No water closet or other plumbing fixture shall be enclosed with any woodwork.
Upcodes Diagrams

Related Code Sections

604.9.2 Plumbing Elements and Facilities, Size
compartment shall be 60 inches (1525 mm) minimum in width measured perpendicular to the side wall, and 56 inches (1420 mm) minimum in depth for wall hung water ...
1109.2.2 Accessibility, Water Closet Compartment
Where water closet compartments are provided in a toilet room or bathing room, at least 5 percent, but not less than one of the total number ...
1109.2.2 Accessibility, Water Closet Compartment
Where water closet compartments are provided in a toilet room or bathing facility, at least one wheelchair-accessible compartment shall be provided ...
1109.2.2 Accessibility, Water Closet Compartment
Where water closet compartments are provided in a toilet room or bathing room, at least one wheelchair-accessible compartment shall be provided ...
1210.3.1 Interior Environment, Water Closet Compartment
Each water closet utilized by the public or employees shall occupy a separate compartment with walls or partitions and a door enclosing the fixtures ...