425.2 Site Work for Manufactured Homes
JUMP TO FULL CODE CHAPTER
Footing design, basements, grading, drainage, decks, stoops, porches and utility connections shall comply with the provisions of this code applicable to Group R-5 occupancies. Additionally, all applicable provisions of Chapter 1 of this code, including but not limited to requirements for permits, inspections, certificates of occupancy and requiring compliance, are applicable to the installation and set-up of a manufactured home. Where the installation or erection of a manufactured home utilizes components that are to be concealed, the installer shall notify the building official that an inspection is necessary and assure that an inspection is performed and approved prior to concealment of such components, unless the building official has agreed to an alternative method of verification.
Installation, set-up, and site work for relocated manufactured homes shall comply with the provisions of this code and shall include the option of using the manufacturer's installations instructions or the federal Model Manufactured Home Installation Standards (24 CFR Part 3285) for the technical requirements.
Alterations and repairs to manufactured homes shall either be in accordance with federal Manufactured Home Construction and Safety Standards (24 CFR Part 3280) or in accordance with the alteration and repair provisions this code.
Additions to manufactured homes shall comply with this code and shall be structurally independent of the manufactured home, or when not structurally independent, shall be evaluated by an RDP to determine that the addition does not cause the manufactured home to become out of compliance with federal Manufactured Home Construction and Safety Standards (24 CFR Part 3280).
Related Code Sections
425.2 Special Detailed Requirements Based on Use and Occupancy, Site Work for Manufactured Homes
Installation, set-up, and site work for relocated manufactured homes shall comply with the provisions of this code and shall include the option ...
2012 Virginia Construction Code (USBC, Part I) > 4 Special Detailed Requirements Based on Use and Occupancy > 425 Manufactured Homes and Industrialized Buildings > 425.2 Site Work for Manufactured Homes
1612.1.1 Structural Design, Elevation of Manufactured Homes
of this code. Exception: Manufactured homes installed on sites in an existing manufactured home park or subdivision shall be permitted ...
2012 Virginia Construction Code (USBC, Part I) > 16 Structural Design > 1612 Flood Loads > 1612.1 General > 1612.1.1 Elevation of Manufactured Homes