• Codes
  • Features

    Features Overview

    Go to features
    Reference

    Reference.

    A reliable and up-to-date source of codes.
    Research

    Research.

    Rapidly and efficiently calculate project parameters.
    Collaboration

    Collaboration.

    Get everyone on the same page and streamline code research.
    Workflows
    Architects General Contractor Building Official & Plans Examiner Inspectors Owner Subcontractors Code Consultants
  • Pricing
  • Login
  • Sign Up
Sign Up
Login
  • Code Library
  • Features
  • Pricing
  • About
  • Careers
  • Help
  • Contact
  • Terms
  • Privacy
Sign Up
Upgrade to Premium
Code calculators: Code Calculators automatically generates a detailed list of requirements.
REFERENCE
Amendment Styling
Industry-leading search
Code diagrams
RESEARCH
Code calculators
Filter by topic
Code compare
Code sheet exports
COLLABORATION
Team projects
Bookmarks
Comments
START 2 WEEK FREE TRIAL
Have an account? Sign in
// CODE SNIPPET

36-593 Site Planning Criteria for Cross Access Connections

NYC Zoning Resolution > III Commercial District Regulations > 6 - Accessory Off-Street Parking and Loading Regulations > 36-50 Additional Regulations for Permitted or Required Accessory Off- Street Parking Spaces > 36-59 Cross Access Connections in the Borough of Staten Island > 36-593 Site Planning Criteria for Cross Access Connections
JUMP TO FULL CODE CHAPTER

Every potential cross access connection meeting the criteria of this Section shall be shown on the site plan required pursuant to Section 36-58 (Parking Lot Maneuverability and Curb Cut Regulations).

(a)        The connection shall be a minimum of 22 feet in width as measured along a lot line or boundary between separate properties when located on the same zoning lot, and at least 23 feet from any street line.

(b)        The connection shall be an extension of a travel lane of the subject open parking lot and align to the maximum extent practicable with a travel lane on any adjacent open parking lot.

(c)        The connection shall have a grade not greater than 15 percent.

(d)        The connection shall be placed in an area that is not blocked by an existing building or other structure that is within 50 feet of the lot line or other boundary of the subject property.

(e)        The connection shall be placed in an area that will not require the removal of significant natural features such as wetlands or trees with a caliper of six inches or more, on the same or adjacent zoning lots.

No screening or landscaping along a lot line shall be required in the connection area.

Related Code Sections


G104.3 Flood-Resistant Construction, Site Plan
The permit application shall include a site plan. The site plan shall include plans and drawings, shall be sealed by a registered design professional ...
NYC Building Code 2014 > G Flood-Resistant Construction > G104 Permits > G104.3 Site Plan
G104.3 Flood-Resistant Construction, Site Plan
The permit application shall include a site plan. The site plan shall include plans and drawings, shall be sealed by a registered design professional ...
NYC Building Code 2008 > G Flood-Resistant Construction > G104 Permits > G104.3 Site Plan
3310.8.2.1 Safeguards During Construction or Demolition, Notification of Conditions to the Department
the crane; No flagperson is present during crane operation where required by this chapter; Sidewalk sheds required by the site safety plan ...
NYC Building Code 2014 > 33 Safeguards During Construction or Demolition > 3310 Requirements for the Construction or Demolition of Major Buildings > 3310.8 Site Safety Manager's and Coordinator's Duties > 3310.8.2 Notification of Violations > 3310.8.2.1 Notification of Conditions to the Department
1104.2 Accessibility, Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces ...
NYC Building Code 2008 > 11 Accessibility > 1104 Accessible Route > 1104.2 Within a Site
1104.2 Accessibility, Within a Site
At least one accessible route shall connect accessible buildings, accessible facilities, accessible elements and accessible spaces ...
NYC Building Code 2014 > 11 Accessibility > 1104 Accessible Route > 1104.2 Within a Site
Help Contact Us Privacy Terms
Code diagrams
Code diagrams
Unpack the code through illustrations and descriptions.
Code Calculators
Code Calculators
Code calculators automatically generate a detailed list of requirements.
Code Compare
Code Compare
Highlight differences between any two building codes.
Search
Search
Don't miss relevant code. Quickly locate sections across your jurisdiction.
Shared projects
Shared projects
Projects provide a dedicated space to collaborate on code research.
Code sheet exports
Code sheet exports
Generate a code sheet that integrates with your drawing set.
UpCodes Premium
Leverage the most sophisticated code compliance platform.
TRY FREE FOR TWO WEEKS VISIT PRICING
UpCodes Premium
Leverage the full code compliance platform.
START 2 WEEK FREE TRIAL LEARN MORE