On a site with multiple nonelevator buildings, the number of units required by Section 1108.7.1 to be Type B units is permitted to be reduced to a percentage that is equal to the percentage of the entire site having grades, prior to development, that are less than 10 percent, provided that all of the following conditions are met:
  1. Not less than 20 percent of the units required by Section 1108.7.1 on the site are Type B units.
  2. Units required by Section 1108.7.1, where the slope between the building entrance serving the units on that story and a pedestrian or vehicular arrival point is not greater than 8.33 percent, are Type B units.
  3. Units required by Section 1108.7.1, where an elevated walkway is planned between a building entrance serving the units on that story and a pedestrian or vehicular arrival point and the slope between them is 10 percent or less, are Type B units.
  4. Units served by an elevator in accordance with Section 1108.7.3 are Type B units.

Related Code Sections

1107.7.4 Accessibility, Site Impracticality
On a site with multiple nonelevator buildings, the number of units required by Section 1107.7.1 to be Type B units is permitted to be reduced ...
1108.7.4 Accessibility, Site Impracticality
On a site with multiple nonelevator buildings, the number of units required by Section 1108.7.1 to be Type B units is permitted to be reduced ...
1509.1 Construction Safeguards, When Required
arrives on the site, on commencement of vertical combustible construction, and on installation of a standpipe system in buildings under ...
3313.1 Safeguards During Construction, Where Required
on the site, on commencement of vertical combustible construction, and on installation of a standpipe system in buildings under construction ...
16.9.10.1 Installation of Piping, Valves, and Appurtenances,
Where it is impractical to provide a post-indicator valve, valves shall be permitted to be placed in pits with permission of the authority having ...