408.2.1 Site Hardscape Materials
Go To Full Code Chapter
Hardscape materials shall have an initial solar reflectance value of not less than 0.30 in accordance with ASTM E 1918 or ASTM C 1549.
Exception: The following materials shall be deemed to comply with this section and need not be tested:
- Pervious and permeable concrete pavements.
- Concrete paving without added color or stain.